Quantitative analysis of respiration-induced motion of each liver segment with helical computed tomography and 4-dimensional computed tomography
نویسندگان
چکیده
BACKGROUND To analyze the respiratory-induced motion of each liver segment using helical computed tomography (helical CT) and 4-dimensional computed tomography (4DCT), and to establish the individual segment expansion margin of internal target volume (ITV) to facilitate target delineation of tumors in different liver segments. METHODS Twenty patients who received radiotherapy with CT-simulation scanning of the whole liver in both helical CT and 10-phase-gated 4DCT were investigated, including 2 patients with esophagus cancer, 4 with lung cancer, 10 with breast cancer, 2 with liver cancer, 1 with thymoma, and 1 with gastric diffuse large B-cell lymphoma (DLBCL). For each patient, 9 representative points were drawn on the helical CT images of liver segments 1, 2, 3, 4a, 4b, 5, 6, 7, and 8, respectively, and adaptively deformed to 2 phases of the 4DCT images at the end of inspiration (phase 0 CT) and expiration (phase 50 CT) in the treatment planning system. Using the amplitude of each point between phase 0 CT and phase 50 CT, we established quantitative data for the respiration-induced motion of each liver segment in 3-dimensional directions. Moreover, using the amplitude between the original helical CT and both 4DCT images, we rendered the individual segment expansion margin of ITV for hepatic target delineation to cover more than 95% of each tumor. RESULTS The average amplitude (mean ± standard deviation) was 0.6 ± 3.0 mm in the left-right (LR) direction, 2.3 ± 2.4 mm in the anterior-posterior (AP) direction, and 5.7 ± 3.4 mm in the superior-inferior (SI) direction, respectively. All of the segments moved posteriorly and superiorly during expiration. Segment 7 had the largest amplitude in the SI direction, at 8.6 ± 3.4 mm. Otherwise, the segments over the lateral side, including segments 2, 3, 6, and 7, had greater excursion in the SI direction compared to the medial segments. To cover more than 95% of each tumor, the required expansion margin of ITV in the LR, AP, and SI directions were at least 2.5 mm, 2.5 mm, and 5.0 mm on average, respectively, with variations between different segments. CONCLUSIONS The greatest excursion occurred in liver segment 7, followed by the segments over the lateral side in the SI direction. The individual segment expansion margin of ITV is required to delineate targets for each segment and direction.
منابع مشابه
Development of a Liver Phantom Based on Computed Tomography Images for Dosimetric Purpose
Introduction: The present study was conducted with the aim of designing a liver phantom for dosimetry. To benchmark the results obtained by the developed liver phantom, another method was applied for the dosimetry of a real liver tissue using imaging. Materials and Methods: For the purpose of the study, a real liver tissue was converted into a phantom based on thegram-molecular weight of the co...
متن کاملRespiratory motion correction in prostate cancer positron emission tomography: A study on patients and phantom simulation
Introduction: To investigate the effects of breathing cycle and tree diaphragm motions on prostate cancer tumors standard uptake value (SUV) during positron emission tomography (PET) and to correct it. Materials and methods: Respiratory motion traces were simulated on the common patient breathing cycle and tree diaphragm motio...
متن کاملPrediction of Human Vertebral Compressive Strength Using Quantitative Computed Tomography Based Nonlinear Finite Element Method
Introduction: Because of the importance of vertebral compressive fracture (VCF) role in increasing the patients’ death rate and reducing their quality of life, many studies have been conducted for a noninvasive prediction of vertebral compressive strength based on bone mineral density (BMD) determination and recently finite element analysis. In this study, QCT-voxel based nonlinear finite eleme...
متن کاملThree-Dimensional Computed Tomography Diagnosis of Cranium Bifidum with Meningocele in a Lamb
Abstract Case Description- A three-day-old male Kordi lamb had a soft painless fluctuating mass on the mid-parietal region, with no clinical signs except difficulty in standing; was referred to the clinic. Clinical Findings- Clinical examination revealed a normal body temperature, a heart rate, a respiratory rate, and inability to stand without any congenital defects Three-dimensional comp...
متن کاملArtifact reduction techniques in Cone Beam Computed Tomography (CBCT) imaging modality
Introduction: Cone beam computed tomography (CBCT) was introduced and became more common based on its low cost, fast image procedure rate and low radiation dose compared to CT. This imaging modality improved diagnostic and treatment-planning procedures by providing three-dimensional information with greatly reduced level of radiation dose compared to 2D dental imaging modalitie...
متن کامل