Acclimatization in wide dynamic range multichannel compression and linear amplification hearing aids.
نویسندگان
چکیده
Acclimatization was studied in hearing-impaired patients with no previous hearing aid (HA) experience who were fit bilaterally with either wide dynamic range multichannel compression (WDRMCC) or linear amplification (LA) HAs. Throughout 40 weeks of normal HA use, we monitored changes in nonsense syllable perception in speech-spectrum noise. Syllable recognition for WDRMCC users improved by 4.6% over the first 8 weeks, but the 2.2% improvement for LA users was complete in 2 to 4 weeks. Consonant confusion analyses indicated that WDRMCC experience facilitated consonant identification, while LA users primarily changed their response biases. Furthermore, WDRMCC users showed greater improvement for aided than unaided stimuli, while LA users did not. These results demonstrate acclimatization in new users of WDRMCC HAs but not in new users of LA HAs. A switch in amplification type after 32 weeks produced minimal performance change. Thus, acclimatization depended on the type of amplification and the previous amplification experience.
منابع مشابه
An evidence-based systematic review of amplitude compression in hearing aids for school-age children with hearing loss.
PURPOSE Two clinical questions were developed: one addressing the comparison of linear amplification with compression limiting to linear amplification with peak clipping, and the second comparing wide dynamic range compression with linear amplification for outcomes of audibility, speech recognition, speech and language, and self- or parent report in children with hearing loss. METHOD Twenty-s...
متن کاملA digital processing strategy to optimize hearing aid outputs directly.
A new amplification strategy (ADRO), based on 64 independently operating channels, was compared with a nine-channel wide dynamic range compression strategy (WDRC). Open-platform in-the-ear hearing instruments were configured either with ADRO or the manufacturer's WDRC strategy. Twenty-two subjects with mild to moderate hearing loss took home the ADRO or WDRC hearing aids. After three weeks' acc...
متن کاملComparison of performance with wide dynamic range compression and linear amplification.
This study compared subject performance and preference using a compression-limiting hearing aid set to linear amplification (program 1) and wide dynamic range compression (WDRC, program 2). The frequency responses of the hearing aid were matched to a 65 dB SPL signal and maximum output to a 90 dB SPL signal. Twenty subjects with moderate to moderately severe sensorineural hearing loss were test...
متن کاملMeasuring the long-term SNRs of static and adaptive compression amplification techniques for speech in noise.
BACKGROUND Multichannel wide-dynamic-range compression (WDRC) is a widely adopted amplification scheme in modern digital hearing aids. It attempts to provide individuals with loudness recruitment with superior speech intelligibility and greater listening comfort over a wider range of input levels. However, recent surveys have shown that compression processing (operating in the nonlinear regime)...
متن کاملLong-term versus short-term hearing aid benefit.
This study compared hearing aid benefit obtained 6 weeks and a minimum of 1 year after fitting to determine if changes occurred over time. Fifteen individuals with mild-to-moderate sensorineural hearing losses, who were successful users of linear amplification, were fitted binaurally with the Resound BT2 Personal Hearing System. These hearing aids are programmable in two frequency bands that pr...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of rehabilitation research and development
دوره 43 4 شماره
صفحات -
تاریخ انتشار 2006