Limit of detection (LQD)/limit of quantitation (LOQ): comparison of the empirical and the statistical methods exemplified with GC-MS assays of abused drugs.
نویسندگان
چکیده
The limit of detection (LOD) for any analytical procedure, the point at which analysis is just feasible, may be determined by a statistical approach based on measuring replicate blank (negative) samples or by an empirical approach, consisting of measuring progressively more dilute concentrations of analyte. The limit of quantitation (LOQ), or concentration at which quantitative results can be reported with a high degree of confidence, may likewise be determined by either approach. We used both methods to determine LOD and LOQ for forensic gas chromatographic-mass spectrometric (GC-MS) analyses of abused drugs. The statistically determined LOD and LOQ values for these assays underestimated the LOD because of the large imprecision associated with blank measurements and the inability of blank samples to meet typical GC-MS acceptance criteria. The empirical method provided much more realistic LOD values, supported by reasonable experimental data, and are 0.5-0.03 the magnitude of the corresponding statistical LODs. The empirical LODs and LOQs are identical for these GC-MS assays. The observations made here about the LOD/LOQ for specific forensic GC-MS procedures are generally applicable to any type of analysis.
منابع مشابه
A Rapid and Sensitive Method for Determina-tion of Morphine in Saliva of Opium Addicts
Background: Saliva is an alternative biological matrix in drug testing. It has several advantages in comparison with other biological fluids such as blood and urine. Collection of saliva is simple, noninvasive and can be controlled under direct observation in drug abusers, or opium addicts. Methods: In the present study we report our experience with saliva collection, liquid-liquid extraction a...
متن کاملDetermination of Benzo[a]pyrene in Traditional, Industrial and Semiindustrial Breads Using a Modified QuEChERS Extraction, Dispersive SPE and GC-MS and Estimation of its Dietary Intake.
A fast and simple modified QuEChERS extraction method was developed for determination of Benzo[a]pyrene (BaP) in 137 traditional (Sangak), semi-industrial (Sangak) and industrial bread samples using spiked calibration curves by GC/MS. Sample preparation includes extraction of BaP into acetone followed by cleanup with dispersive solid phase extraction. The limit of detection and limit of quantif...
متن کاملDetermination of Benzo[a]pyrene in Traditional, Industrial and Semiindustrial Breads Using a Modified QuEChERS Extraction, Dispersive SPE and GC-MS and Estimation of its Dietary Intake.
A fast and simple modified QuEChERS extraction method was developed for determination of Benzo[a]pyrene (BaP) in 137 traditional (Sangak), semi-industrial (Sangak) and industrial bread samples using spiked calibration curves by GC/MS. Sample preparation includes extraction of BaP into acetone followed by cleanup with dispersive solid phase extraction. The limit of detection and limit of quantif...
متن کاملDevelopment of Sensitive and Specific Analysis of Vildagliptin in Pharmaceutical Formulation by Gas Chromatography-Mass Spectrometry
A sensitive and selective gas chromatography-mass spectrometry (GC-MS) method was developed and fully validated for the determination of vildagliptin (VIL) in pharmaceutical formulation. Prior to GC-MS analysis, VIL was efficiently derivatized with MSTFA/NH4I/β-mercaptoethanol at 60°C for 30 min. The obtained O-TMS derivative of VIL was detected by selected ion monitoring mode using the diagnos...
متن کاملApplication of Dispersive Liquid-Liquid Microextraction to Determine Aflatoxin B1 in Tomato Paste Samples
Background: Aflatoxin B1 is a secondary toxic metabolite produced by several aspergillus species. This study was conducted to determine the presence of aflatoxin in tomato paste samples. Methods: A total of 30 tomato pastes were analyzed for Aflatoxin B1 contamination via HPLC-FLD. Analyte extraction was done by dispersive liquid-liquid microextraction. Results: The limit of detection (LOD) and...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Clinical chemistry
دوره 40 7 Pt 1 شماره
صفحات -
تاریخ انتشار 1994