Relationship between screw sagittal angle and stress on endplate of adjacent segments after anterior cervical corpectomy and fusion with internal fixation: a Chinese finite element study

نویسندگان

  • Yu Zhang
  • Yibo Tang
  • Hongxing Shen
چکیده

BACKGROUND In order to reduce the incidence of adjacent segment disease (ASD), the current study was designed to establish Chinese finite element models of normal 3rd~7th cervical vertebrae (C3-C7) and anterior cervical corpectomy and fusion (ACCF) with internal fixation , and analyze the influence of screw sagittal angle (SSA) on stress on endplate of adjacent cervical segments. METHODS Mimics 8.1 and Abaqus/CAE 6.10 softwares were adopted to establish finite element models. RESULTS For C4 superior endplate and C6 inferior endplate, their anterior areas had the maximum stress in anteflexion position, and their posterior areas had the maximum stress in posterior extension position. As SSA increased, the stress reduced. With an increase of 10° in SSA, the stress on anterior areas of C4 superior endplate and C6 inferior endplate reduced by 12.67% and 7.99% in anteflexion position, respectively. With an increase of 10° in SSA, the stress on posterior areas of C4 superior endplate and C6 inferior endplate reduced by 9.68% and 10.22% in posterior extension position, respectively. CONCLUSIONS The current study established Chinese finite element models of normal C3-C7 and ACCF with internal fixation , and demonstrated that as SSA increased, the stress on endplate of adjacent cervical segments decreased. In clinical surgery, increased SSA is able to play important role in protecting the adjacent cervical segments and reducing the incidence of ASD.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Novel Anterior Transpedicular Screw Artificial Vertebral Body System for Lower Cervical Spine Fixation: A Finite Element Study.

A finite element model was used to compare the biomechanical properties of a novel anterior transpedicular screw artificial vertebral body system (AVBS) with a conventional anterior screw plate system (ASPS) for fixation in the lower cervical spine. A model of the intact cervical spine (C3-C7) was established. AVBS or ASPS constructs were implanted between C4 and C6. The models were loaded in t...

متن کامل

Comparison of short-segment monoaxial and polyaxial pedicle screw fixation combined with intermediate screws in traumatic thoracolumbar fractures: a finite element study and clinical radiographic review

OBJECTIVES No studies have compared monoaxial and polyaxial pedicle screws with regard to the von Mises stress of the instrumentation, intradiscal pressures of the adjacent segment and adjacent segment degeneration. METHODS Short-segment monoaxial/polyaxial pedicle screw fixation techniques were compared using finite element methods, and the redistributed T11-L1 segment range of motion, large...

متن کامل

Effect of anterior cervical discectomy and fusion on adjacent segments in rabbits.

This study is to investigate the effect of anterior cervical discectomy with internal fixation and fusion at different levels on adjacent segments in rabbits. Sixty New Zealand rabbits were randomly divided into four groups, one control group and three model groups, with 15 in each group. Each group underwent anterior cervical internal fixation and fusion at C3-4, C4-5, and C5-6 levels respecti...

متن کامل

Efficacy and safety of the use of titanium mesh cages and anterior cervical plates for interbody fusion after anterior cervical corpectomy.

BACKGROUND To determine the safety and effectiveness of the use of titanium mesh cages (TMCs) and anterior cervical plates (ACPs) for interbody fusion after anterior cervical corpectomy. METHODS From June 2001 to June 2003, 15 patients underwent reconstruction with TMCs and ACPs for interbody fusion after anterior cervical corpectomy in our hospital. The mean follow-up is 13.6 months (range, ...

متن کامل

Clinical Efficacy of Anterior Partial Corpectomy and Titanium Mesh Fusion and Internal Fixation for Treatment of Old Fracture Dislocation of the Lower Cervical Spine

BACKGROUND The aim of this study was to analyze the clinical features and to evaluate the efficacy of anterior partial corpectomy and titanium mesh fusion and internal fixation of old fracture dislocation of the lower cervical spine. MATERIAL AND METHODS We retrospectively analyzed the clinical data of 52 patients with old lower cervical fracture and dislocation treated with anterior partial co...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 17  شماره 

صفحات  -

تاریخ انتشار 2017