Comparative Study of Duolite A - 378 and Duolite A - 143 Anion Exchange Resins by Application of 131 I and 82 Br as a Tracer Isotopes
نویسنده
چکیده
In the present study radioactive tracer isotopes I and Br are applied to study the kinetics of iodide and bromide ion-isotopic exchange reactions in two anion exchange resins Duolite A-378 and Duolite A-143. The study is performed by varying the experimental parameters like temperature and concentration of exchanging medium to understand the effect of above parameters on exchange reaction rate (min), amount of ions exchanged (mmol), percentage of ions exchanged and distribution coefficient. For both the ion-isotopic exchange reactions it is common observation that the exchange reaction rate increases with increase in concentration and decreases with rise in temperature of exchanging med ium. Also there exists a strong positive co-relationship between amount of ions exchanged and concentration of ionic solution, while a strong negative co-relationship exists between amounts of ions exchanged and temperature of exchanging medium. Comparing the values of reaction rate (min), amount of ions exchanged (mmol); percentage of ions exchanged and distribution coefficient calculated for the two resins, it is observed that Duolite A-378 resins show superior performance than Duolite A-143 resins under identical operational parameters.
منابع مشابه
Performance Based Evaluation of Industrial Grade Resins Duolite ARA-9366 and Duolite A-368
Ion exchange resins are used in several chemical decontamination or cleaning processes and in nuclear industries for removal of radionuclides.1–5 Nowadays, ion exchange resins are not only used for separation but also as catalysts. In the past decade, inorganic ion exchange materials have emerged as an increasingly important replacement or complement to conventional organic ion exchange resins....
متن کاملSynthesis, characterization and application of iron (III) - loaded duoilite C26 adsorbent for arsenic removal
Iron(III) was loaded onto the sulphonic acid sites of Duolite C26, a commercial cation-exchanger, and was then converted into hydrated ferric oxides (HFO) disbursed throughout the macropores of the ion exchanger beads. The resulting hydrated iron(III)-oxide loaded cation exchange resin (HFOLR) was tested for its ability to remove arsenate [As(V)] ions present in water by batch technology. The s...
متن کاملPolysulfone-based Anion Exchange Membranes for Potential Application in Solid Alkaline Fuel Cells
In present research work, anion exchange membranes based on quaternized polysulfone with ammonium cation moieties (QAPSF) were prepared by chloromethylation, amination and alkalization. The chloromethylated polysulfone were characterized by 1HNMR spectroscopy and functionalization degree was determined according to peak area integration. Ion transport properties (ionic conductivity, ion exchang...
متن کاملDrug Resinates an Attractive Approach of Solubility Enhancement of Atorvastatin Calcium
A substantial number of new chemical entities and marketed drugs show poor solubility characteristics and amorphisation is one of the favorable approaches to enhance solubility characteristics of such poorly soluble drugs. Formulation efforts in the present study were devoted to investigate amorphisation of a model poorly soluble drug, atorvastatin calcium by molecular complexation with anion e...
متن کاملComparison of Absorbed Fraction of Gamma and Beta Rays of I-124 and I-131radio-Isotopes in Thyroid Gland with Monte Carlo Simulation
I131 is a famous radio-iodine isotope in use for diagnosis and treatment of hyper functioning and cancerous thyroid gland. It is a nuclear reactor product; however nuclear reactor may be unavailable in some areas. Replacement by I-124 may be possible, another iodine isotope producible by cyclotron; a system more available than reactor. Here absorbed fraction of Gamma and Beta rays of...
متن کامل