The proximity-fixation-disparity curve and the preferred viewing distance at a visual display as an indicator of near vision fatigue.

نویسنده

  • Wolfgang Jaschinski
چکیده

PURPOSE This laboratory study investigates the relation between measures of fixation disparity (FD) (and other optometric measures) and near vision fatigue at a computer workstation. METHODS Young adult subjects with normal binocular vision performed three blocks of a visual task of 30 min each. In Block A, the viewing distance was 100 cm, as a reference without near vision. In Block B, the viewing distance of 50 cm induced a defined near vision load. In Block C, subjects were free to choose a comfortable viewing distance. This preferred viewing distance was used as an indicator of near vision fatigue because subjects adopting longer viewing distances in Block C had more near vision fatigue at 50 cm in Block B. RESULTS Subjects with preferred viewing distances longer than average (63 cm) had steeper slopes of FD as a function of viewing distance (100-30 cm), as shown by discriminant analyses. CONCLUSIONS Thus, this steep proximity-FD curve indicates a weak disparity vergence system that may cause near vision fatigue. This may explain why some young adults prefer longer viewing distances at the computer workstation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Individual Objective and Subjective Fixation Disparity in Near Vision

Binocular vision refers to the integration of images in the two eyes for improved visual performance and depth perception. One aspect of binocular vision is the fixation disparity, which is a suboptimal condition in individuals with respect to binocular eye movement control and subsequent neural processing. The objective fixation disparity refers to the vergence angle between the visual axes, w...

متن کامل

Fixation disparity and accommodation for stimuli closer and more distant than oculomotor tonic positions

Both the vergence and the accommodative system have individual tonic positions (also referred to as dark vergence and dark focus, respectively) where the static response may be expected to be most accurate. This was confirmed by measuring fixation disparity with nonius lines and accommodation with an autorefractometer for foveal stimuli at viewing distances of 460, 100, 60, 40, and 30 cm. Multi...

متن کامل

Distance impairs postural stability only under binocular viewing

Prior studies indicate that postural stability under binocular viewing is not better than under monocular viewing. This was tested at the distances of 145 cm [Fox, C.R. (1990). Some visual influences on human postural equilibrium: binocular versus monocular fixation. Perception and Psychophysics, 47 (5), 409-422] and 90 cm [Isotalo, E., Kapoula, Z., Feret, P.H., Gauchon, K., Zamfirescu, F., & G...

متن کامل

True Three-Dimensional Displays that Allow Viewers to Dynamically Shift Accommodation, Bringing Objects Displayed at Different Viewing Distances Into and Out of Focus

Under natural viewing conditions, viewers do not just passively perceive. Instead, they dynamically scan the visual scene by shifting their eye fixation and focus between objects at different viewing distances. In doing so, the oculomotor processes of accommodation (eye focus) and vergence (angle between lines of sight of two eyes) must be shifted synchronously to place new objects in sharp foc...

متن کامل

Are blur and disparity complementary cues to depth?

The image blur and binocular disparity of a 3D scene point both increase with distance in depth away from fixation. Perceived depth from disparity has been studied extensively and is known to be most precise near fixation. Perceived depth from blur is much less well understood. A recent experiment (Held, R. T, Cooper, E. A., & Banks, M. S. (2012). Current Biology, 22, 426-431) which used a volu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Optometry and vision science : official publication of the American Academy of Optometry

دوره 79 3  شماره 

صفحات  -

تاریخ انتشار 2002