Precision Flow Control and Enhanced Filter Lifetime in Magnetically Levitated Pump Based CMP Slurry Delivery Systems
نویسندگان
چکیده
AND CONCLUSIONS Chemical Mechanical Planarization (CMP) must continuously improve to meet the stringent requirements of next generation IC device manufacturing. Precision flow control of CMP slurry is critical to achieving a repeatable planarization process, minimizing slurry waste, and reducing cost-of-ownership (CoO). Monitoring and controlling slurry large particle concentration through filtration is also essential in maintaining slurry health during its lifecycle. This study reports data of slurry handling, filtration, and flow control using magnetically levitated centrifugal (MLC) pumps and airoperated double diaphragm (AOD) pumps. Results are presented for a point-of-use (POU) slurry delivery system feeding from a simulated global distribution loop. Tests were performed using ~12.5 (Silica-I) and ~25 (Silica-II) weight percentage of solids silica abrasive oxide CMP slurries. Extensive handling tests of shear-sensitive silica slurries using an AOD pump generated significant number of large particle agglomerates. In similar tests, an MLC pump generated fewer large particles than an AOD pump for comparable turnovers. A filter of nominal rating 1.0 micron was used in the global loop for these tests. In comparison to similar AOD pumps, slurry recirculation tests using an MLC pump in five-hour recirculation tests (with one-micron pleated-depth-filter in the loop), show a much smaller increase in filter pressure-drop and minimal slurry loop pressure pulsation with time. This would suggest significantly enhanced filter lifetime for the MLC pump based slurry delivery systems handling shear sensitive silica slurries, as compared with the AOD pump systems. Evaluation of a closed-loop flow-control system employing a pre-pressure regulator, an MLC pump, and a differential pressure based electronic flowmeter in the slip stream demonstrated good functionality and dispense flow consistency, and resulted in repeatable short-term and extended-period slurry dispense cycles over the tested flow range of 50 mL/min to 490 mL/min. This approach will provide significant benefits in advanced CMP processes by eliminating inconsistent slurry flow and particle contamination from peristaltic pump tubing, enhancing filter lifetime, increasing device yield, reducing the possibility of catastrophic failure, and minimizing downtime and labor costs due to frequent pump maintenance and replacement.
منابع مشابه
Proper Filtration Removes Oversized Particles from CMP Slurry Systems
Single stage recirculation filtrations were performed to remove oversized particles from colloidal silica based Chemical Mechanical Polishing (CMP) slurry. Proper filtration was demonstrated to achieve rapid removal of oversized particles while not altering the percent solids of the CMP slurry. Mathematical models were developed to simulate particle reduction in CMP slurry distribution systems....
متن کاملFully Magnetically Levitated Left Ventricular Assist System for Treating Advanced HF: A Multicenter Study.
BACKGROUND The HeartMate 3 left ventricular assist system (LVAS) is intended to provide long-term support to patients with advanced heart failure. The centrifugal flow pump is designed for enhanced hemocompatibility by incorporating a magnetically levitated rotor with wide blood-flow paths and an artificial pulse. OBJECTIVES The aim of this single-arm, prospective, multicenter study was to ev...
متن کاملSliding-mode control of a nonlinear-input system: application to a magnetically levitated fast-tool servo
Magnetic servo levitation (MSL) is currently being investigated as an alternative to drive fast-tool servo systems that could overcome the range limitations inherent to piezoelectric driven devices while operating over a wide bandwidth. To control such systems, a feedback-linearized controller coupled with a Kalman filter has been previously described. Performance limitations that degrade track...
متن کاملOptimization of a Hybrid Magnetic Bearing for a Magnetically Levitated Blood Pump via 3-D FEA.
In order to improve the performance of a magnetically levitated (maglev) axial flow blood pump, three-dimensional (3-D) finite element analysis (FEA) was used to optimize the design of a hybrid magnetic bearing (HMB). Radial, axial, and current stiffness of multiple design variations of the HMB were calculated using a 3-D FEA package and verified by experimental results. As compared with the or...
متن کاملA High-Precision, Magnetically Levitated Positioning Stage
High accuracy positioning stages with multiple degrees-of-freedom, or microsteppers, are ubiquitous in industrial manufacturing. These devices are used in probing and inspection systems, in the assembly of disk drive heads, and in semiconductor manufacturing. In semiconductor manufacturing, microsteppers are employed to accurately move silicon wafers in the photolithography process. To guarante...
متن کامل