The Role of Additional Pulses in Electropermeabilization Protocols

نویسندگان

  • Cecilia Suárez
  • Alejandro Soba
  • Felipe Maglietti
  • Nahuel Olaiz
  • Guillermo Marshall
چکیده

Electropermeabilization (EP) based protocols such as those applied in medicine, food processing or environmental management, are well established and widely used. The applied voltage, as well as tissue electric conductivity, are of utmost importance for assessing final electropermeabilized area and thus EP effectiveness. Experimental results from literature report that, under certain EP protocols, consecutive pulses increase tissue electric conductivity and even the permeabilization amount. Here we introduce a theoretical model that takes into account this effect in the application of an EP-based protocol, and its validation with experimental measurements. The theoretical model describes the electric field distribution by a nonlinear Laplace equation with a variable conductivity coefficient depending on the electric field, the temperature and the quantity of pulses, and the Penne's Bioheat equation for temperature variations. In the experiments, a vegetable tissue model (potato slice) is used for measuring electric currents and tissue electropermeabilized area in different EP protocols. Experimental measurements show that, during sequential pulses and keeping constant the applied voltage, the electric current density and the blackened (electropermeabilized) area increase. This behavior can only be attributed to a rise in the electric conductivity due to a higher number of pulses. Accordingly, we present a theoretical modeling of an EP protocol that predicts correctly the increment in the electric current density observed experimentally during the addition of pulses. The model also demonstrates that the electric current increase is due to a rise in the electric conductivity, in turn induced by temperature and pulse number, with no significant changes in the electric field distribution. The EP model introduced, based on a novel formulation of the electric conductivity, leads to a more realistic description of the EP phenomenon, hopefully providing more accurate predictions of treatment outcomes.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cell membrane electropermeabilization by symmetrical bipolar rectangular pulses. Part I. Increased efficiency of permeabilization.

The paper presents a comparative study of electropermeabilization of cells in suspension by unipolar and symmetrical bipolar rectangular electric pulses. While the parameters of electropermeabilization by unipolar pulses have been investigated extensively both in cell suspensions and in tissues, studies using bipolar pulses have been rare, partly due to the lack of commercially available bipola...

متن کامل

Role of pulse shape in cell membrane electropermeabilization.

The role of the amplitude, number, and duration of unipolar rectangular electric pulses in cell membrane electropermeabilization in vitro has been the subject of several studies. With respect to unipolar rectangular pulses, an improved efficiency has been reported for several modifications of the pulse shape: separate bipolar pulses, continuous bipolar waveforms, and sine-modulated pulses. In t...

متن کامل

The temperature effect during pulse application on cell membrane fluidity and permeabilization.

Cell membrane permeabilization is caused by the application of high intensity electric pulses of short duration. The extent of cell membrane permeabilization depends on electric pulse parameters, characteristics of the electropermeabilization media and properties of cells exposed to electric pulses. In the present study, the temperature effect during pulse application on cell membrane fluidity ...

متن کامل

Cell membrane electropermeabilization with arbitrary pulse waveforms.

xposure of a biological cell to an electric field can produce a variety of responses [1]-[6]. If the field strength exceeds a certain threshold value, this leads to a large transient increase in membrane conductivity and permeability for ions and molecules (electropermeabilization, often also named electroporation) or to fusion of adjacent cells (electrofusion) [5], [6]. Nowadays, these phenome...

متن کامل

Cell membrane electropermeabilization by symmetrical bipolar rectangular pulses. Part II. Reduced electrolytic contamination.

The paper presents a comparative study of the contamination of a cell suspension by ions released from aluminum cuvettes (Al(3+)) and stainless steel electrodes (Fe(2+)/Fe(3+)) during cell membrane electropermeabilization by unipolar and by symmetrical bipolar rectangular electric pulses. A single pulse and a train of eight pulses were delivered to electrodes at a 2-mm distance, with 100-micros...