[Study on patch test reagent for titanium].
نویسنده
چکیده
Recently, allergy to titanium has been reported. However, the patch test reagent for titanium is not standardized yet. The form and density of the patch test reagent for titanium was changed and examined in a group of normal subjects and a group with skin disease. The following conclusions were obtained. 1. A reagent which was composed of pure titanium powder and vaseline was not preferable because its form was a stimulant. 2. If the form of the titanium powder was not sharp even though it was not spherical, it did not cause a stimulated reaction. 3. It is suggested that TiCl4 0.1% is preferable as a patch test reagent for titanium.
منابع مشابه
Sirolimus-eluting stents suppress neointimal formation irrespective of metallic allergy.
BACKGROUND Metallic allergy is associated with restenosis following bare metal stent implantation, but the impact of metallic allergy on the outcome after implantation of drug-eluting stents (DES) has not been investigated. METHODS AND RESULTS The present study group consisted of 88 consecutive patients (109 lesions) who underwent percutaneous coronary intervention with sirolimus-eluting sten...
متن کاملMetals Are Important Contact Sensitizers: An Experience from Lithuania
Background. Metals are very frequent sensitizers causing contact allergy and allergic contact dermatitis worldwide; up-to-date data based on patch test results has proved useful for the identification of a problem. Objectives. In this retrospective study prevalence of contact allergy to metals (nickel, chromium, palladium, gold, cobalt, and titanium) in Lithuania is analysed. Patients/Methods. ...
متن کاملHypersensitivity to titanium: clinical and laboratory evidence.
OBJECTIVES This study was carried out to investigate the potential of titanium to induce hypersensitivity in patients chronically exposed to titanium-based dental or endoprosthetic implants. METHODS Fifty-six patients who had developed clinical symptoms after receiving titanium-based implants were tested in the optimized lymphocyte transformation test MELISA against 10 metals including titani...
متن کاملAllergic reaction to vanadium causes a diffuse eczematous eruption and titanium alloy orthopedic implant failure.
Allergy as a cause of adverse outcomes in patients with implanted orthopedic hardware is controversial. Allergy to titanium-based implants has not been well researched, as titanium is traditionally thought to be inert. We highlight the case of a patient who developed systemic dermatitis and implant failure after surgical placement of a titanium alloy (Ti6Al4V) plate in the left foot. The hardwa...
متن کاملTriple metal-hypersensitivity in the patient with knee prosthesis: a rare case
Case presentation A 70-years old healthy male patient presented in our clinic with a recurrent swelling, redness and limitation of movement of his right knee. Clinical examination and laboratory findings showed no evidence of bacterial infection of the joint. The patient had no other complaints. According to the clinical history the patient received titanium prosthesis of the right knee in 2009...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Kokubyo Gakkai zasshi. The Journal of the Stomatological Society, Japan
دوره 74 2 شماره
صفحات -
تاریخ انتشار 2007