Stability of antimicrobial activity of peracetic acid solutions used in the final disinfection process.

نویسندگان

  • Solange Alves da Silva Costa
  • Olívia Ferreira Pereira de Paula
  • Célia Regina Gonçalves E Silva
  • Mariella Vieira Pereira Leão
  • Silvana Soléo Ferreira dos Santos
چکیده

The instruments and materials used in health establishments are frequently exposed to microorganism contamination, and chemical products are used before sterilization to reduce occupational infection. We evaluated the antimicrobial effectiveness, physical stability, and corrosiveness of two commercial formulations of peracetic acid on experimentally contaminated specimens. Stainless steel specimens were contaminated with Staphylococcus aureus, Escherichia coli, Candida albicans, blood, and saliva and then immersed in a ready peracetic acid solution: 2% Sekusept Aktiv (SA) or 0.25% Proxitane Alpha (PA), for different times. Then, washes of these instruments were plated in culture medium and colony-forming units counted. This procedure was repeated six times per day over 24 non-consecutive days. The corrosion capacity was assessed with the mass loss test, and the concentration of peracetic acid and pH of the solutions were measured with indicator tapes. Both SA and PA significantly eliminated microorganisms; however, the SA solution was stable for only 4 days, whereas PA remained stable throughout the experiment. The concentration of peracetic acid in the SA solutions decreased over time until the chemical was undetectable, although the pH remained at 5. The PA solution had a concentration of 500-400 mg/L and a pH of 2-3. Neither formulation induced corrosion and both reduced the number of microorganisms (p = 0.0001). However, the differences observed in the performance of each product highlight the necessity of establishing a protocol for optimizing the use of each one.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Disinfection of wastewater with peracetic acid: a review.

Peracetic acid is a strong disinfectant with a wide spectrum of antimicrobial activity. Due to its bactericidal, virucidal, fungicidal, and sporicidal effectiveness as demonstrated in various industries, the use of peracetic acid as a disinfectant for wastewater effluents has been drawing more attention in recent years. The desirable attributes of peracetic acid for wastewater disinfection are ...

متن کامل

Evaluation of Disinfection of Gutta‐ Percha Cones Using Different Chemical Solutions

Background: Disinfection and sterilization of obturating materials in the root canal is necessary for the successful root canal therapy. Various disinfectants have been used to sterilize and disinfect gutta‐ percha including sodium hypochlorite (NaOCl), chlorohexidine (CHx), etc. . Effectiveness of peracetic acid over NaOCl is documented in literature, but no study to date has shown the effect ...

متن کامل

Use of 0.25% and 0.025% peracetic acid as disinfectant agent for chemically activated acrylic resin: an in vitro study

Objective This in vitro study evaluated the disinfection action of peracetic acid on chemically activated acrylic resin. Methods Sixty chemically activated acrylic resin specimens were contaminated with Candida albicans (30) and Bacillus subtilis (30) for 15 minutes. Next, specimens were divided into Control Group (Group 0) and Test Group (T) for each studied microorganism. The antimicrobial ef...

متن کامل

Antimicrobial and structural effects of different irrigation solutions on gutta-percha cones

PURPOSE To evaluate the alterations on the surface of gutta-percha cones (GPCs) on exposure to the different irrigation solutions and their possible antibacterial effect against Enterococcus faecalis. (E. faecalis). MATERIALS AND METHODS Disinfection ability of different solutions (5.25% sodium hypochlorite, 2% chlorhexidine, 1% peracetic acid, and QMix) were tested with 96 GPCs and the time ...

متن کامل

تجزیه رنگ متیلن بلو با استفاده از فرآیند های فنتون/فتو فنتون-پراستیک اسید ( UV/Fe3+-CH3COOH−H2O2) از محیط های آبی

Background and purpose: Industries are one of the main sources of producing wastewater accounting for 20% of water pollution. Treatment of dye wastewaters is one of the major challenges in textile industry. The aim of this study was to investigate the performance of advanced oxidation processes, Fenton-Peracetic acid and Photo-Fenton-Peracetic acid for removal of methylene blue (MB) dye from ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Brazilian oral research

دوره 29  شماره 

صفحات  -

تاریخ انتشار 2015