Geostatistics - a tool applied to the distribution of Legionella pneumophila in a hospital water system.
نویسندگان
چکیده
INTRODUCTION Legionnaires' disease is normally acquired by inhalation of legionellae from a contaminated environmental source. Water systems of large buildings, such as hospitals, are often contaminated with legionellae and therefore represent a potential risk for the hospital population. The aim of this study was to evaluate the potential contamination of Legionella pneumophila (LP) in a large hospital in Italy through georeferential statistical analysis to assess the possible sources of dispersion and, consequently, the risk of exposure for both health care staff and patients. MATERIALS AND METHOD LP serogroups 1 and 2-14 distribution was considered in the wards housed on two consecutive floors of the hospital building. On the basis of information provided by 53 bacteriological analysis, a 'random' grid of points was chosen and spatial geostatistics or FAIk Kriging was applied and compared with the results of classical statistical analysis. RESULTS Over 50% of the examined samples were positive for Legionella pneumophila. LP 1 was isolated in 69% of samples from the ground floor and in 60% of sample from the first floor; LP 2-14 in 36% of sample from the ground floor and 24% from the first. The iso-estimation maps show clearly the most contaminated pipe and the difference in the diffusion of the different L. pneumophila serogroups. CONCLUSION Experimental work has demonstrated that geostatistical methods applied to the microbiological analysis of water matrices allows a better modeling of the phenomenon under study, a greater potential for risk management and a greater choice of methods of prevention and environmental recovery to be put in place with respect to the classical statistical analysis.
منابع مشابه
Investigation of Legionella Pneumophila bacteria in hospital water supply systems
Introduction: Legionella Pneumophila bacteria is known as one of the most important nosocomial infections and the most common cause of death in patients. This study was aimed to identify Legionella Pneumophila bacteria in hospital water supply systems. Material and Methods: This descriptive cross-sectional study was performed to identify Legionella pneumophila in hot and cold-water systems of i...
متن کاملIsolation of Legionella pneumophila from Tehran Hospital Water Samples
Over a Period of three months (summer), 108 samples of water collected from four hospitals in Te-hran. They were taken from numerous potable and non-potable water, including main supply cis-terns, calorifiers, hot and cold tap water, shower, cooling tower and drain of air condition system. Culturing of concentrated and non-concentrated water samples on Buffered Charcoal Yeast Extract (BCYE) Aga...
متن کاملPrevalence of Legionella Species in Water Resources of Iran: A Systematic Review and Meta-Analysis
Background: Legionella species are ubiquitous and naturally found in lakes, rivers, streams and hot springs, and other water resources. The present study aimed to investigate the prevalence of Legionella species in water resources of Iran by a systematic review and meta-analysis.Methods: In search of papers relevant to the prevalence of Legionella in water resources of Iran, the scientific info...
متن کاملفراوانی لژیونلا پنوموفیلا در شیر آب سرد و گرم و مخزن آب انکوباتورهای بخش نوزادان بیمارستانهای گیلان
Background and purpose: Nosocomial outbreaks of legionnaires’ diseases are usually related to contamination of water sources. This survey investigated the frequency of mip gene in cold and warm water taps and water containers of infant incubators containing legionella pneumophila in hospitals of Guilan province, Iran. Materials and methods: This cross-sectional study used 140 samples. They wer...
متن کاملAn Investigation of the Legionella Pneumophila Infection in Pneumonic Patients in Three Different Infections Hospital Wards in Tehran
Legionella pneumophila is one of the causative agent of pneumonia in human being. In recent years many reports has been come from different parts of world regarding infectivity of this organism. This disease occurs almost because of contamination of air conditioning systems. For the purpose of assessment of the legionella pneumophila in pneumonic patients, 200 specimen from sputum and tracheo-b...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Annals of agricultural and environmental medicine : AAEM
دوره 22 4 شماره
صفحات -
تاریخ انتشار 2015