Influence of demographic, surgical and implant variables on wear rate and osteolysis in ABG I hip arthroplasty.

نویسندگان

  • Jiri Gallo
  • Vitezslav Havranek
  • Ivana Cechova
  • Jana Zapletalova
چکیده

Periprosthetic osteolysis is associated with accelerated wear rates. The goal of this study was to investigate the influence of demographic and technical variables on wear rates and size of osteolytic lesions. Eighty retrieved ABG I prostheses were analyzed according to prospectively established criteria. There were 22 men and 58 women with an average age of 52 years (34-65) at the time of revision. The average time from index surgery to revision was 67 months (26 to 106). Polyethylene wear measurements were performed using a Universal-type measuring microscope. The average linear wear and volumetric wear rate was 0.363 mm per year (0-0.939, SD 0.241) and 161 mm(3) per year (0-467, SD 118.2), respectively. The wear rates were significantly higher (a) in patients with primary osteoarthritis in comparison with postdysplastic hips, (b) in hips where zirconia prosthetic heads articulated against the polyethylene liner, and (c) in cups placed laterally to Kohler's line. Risk that linear wear rate could be more than 0.2 mm per year was three times higher in patients who were operated in 1997 and later (OR 3.0, 95 % CI 1.126-7.993, p = 0.03). A strong association was revealed between magnitude of wear and size of femoral osteolysis.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Male gender, Charnley class C, and severity of bone defects predict the risk for aseptic loosening in the cup of ABG I hip arthroplasty

BACKGROUND We studied which factor could predict aseptic loosening in ABG I hip prosthesis with hydroxyapatite coating. Aseptic loosening and periprosthetic osteolysis are believed to be caused, at least in part, by increased polyethylene (PE) wear rate via particle disease. Based on it, increased PE wear rate should be associated with aseptic loosening regardless of the type of implant. METH...

متن کامل

Premature wear and osteolysis in an HA-coated, uncemented total hip arthroplasty.

The ABG I cementless hip prosthesis has demonstrated unacceptably high rates of wear and osteolysis in our patients. We performed a retrospective study of 97 hips implanted between 1992 and 1998. Radiographic analysis revealed high rates of wear of the polyethylene liner with marked peri-acetabular osteolysis. Clinical examination indicated that many of these patients were initially asymptomati...

متن کامل

Poor survival of ABG I hip prosthesis in younger patients.

BACKGROUND Hydroxyapatite coated (HAC) hip implants have been used in clinical practice for more than two decades. However, the majority of studies have reported only intermediate term outcomes that are not reliable for predicting long-term behavior in all implants. The aim of this study was to determine the performance of HAC total hip arthroplasty in younger patients over a 10-year follow-up ...

متن کامل

Comparison of Hydroxyapatite-coated stems in total hip arthroplasty after a minimum 10-years follow-up.

PURPOSE OF THE STUDY Hydroxypatite coating (HAC) was introduced into total hip arthroplasty (THA) practice to improve the fixation interface between bone and prosthesis. To test this assumption however, long-term follow-up investigations are needed. In this study, we present data for two consecutive series of THA stems with HAC and a minimum ten-year follow-up. MATERIAL Overall, 249 patients (2...

متن کامل

Saving Implants BMP-2 Application in Revision Total Hip Surgery

OBJECTIVE Besides others, there are two major problems in total hip replacement surgery which result in implant failure. First there is aseptic loosening due to a lack of implant biocompatibility or micromovements and second periimplant wear debris induced osteolysis which limits the survival rate of an implant. Regarding to recent data there are only limited therapeutic strategies to heal thes...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Biomedical papers of the Medical Faculty of the University Palacky, Olomouc, Czechoslovakia

دوره 150 1  شماره 

صفحات  -

تاریخ انتشار 2006