Two-center collaborative evaluation of the performance of the BD Phoenix automated microbiology system for identification and antimicrobial susceptibility testing of Enterococcus spp. and Staphylococcus spp.
نویسندگان
چکیده
The performance of the BD Phoenix Automated Microbiology System (BD Diagnostic Systems, Sparks, Md.) was assessed for identification (ID) and antimicrobial susceptibility testing (AST) for the majority of clinically encountered bacterial isolates in a European collaborative two-center trial. A total of 469 bacterial isolates of the genera Staphylococcus (275 isolates), Enterococcus (179 isolates), and Streptococcus (15 isolates, for ID only) were investigated; of these, 367 were single patient isolates, and 102 were challenge strains tested at one center. Sixty-four antimicrobial drugs were tested, including the following drug classes: aminoglycosides, beta-lactam antibiotics, beta-lactam-beta-lactamase inhibitors, carbapenems, cephems, folate antagonists, quinolones, glycopeptides, macrolides-lincosamides-streptogramin B (MLS), and others. Phoenix ID results were compared to those of the laboratories' routine ID systems (API 32 Staph, API 32 Strep, and VITEK 2 [bioMérieux, Marcy l'Etoile, France]); Phoenix AST results were compared to those of frozen standard broth microdilution (SBM) panels according to NCCLS guidelines (NCCLS document M 100-S 9, approved standard M 7-A 4). Discrepant results were repeated in duplicate. Concordant IDs of 97.1, 98.9, and 100% were observed for staphylococci, enterococci, and streptococci, respectively. For AST results the overall essential agreement was 93.3%; the category agreement was 97.3%; and the very major error rate, major error rate, and minor error rate were 1.2, 1.9, and 1.3%, respectively. In conclusion, the Phoenix ID results showed high agreement with results of the systems to which they were being compared; the AST performance was highly equivalent to that of the SBM reference method.
منابع مشابه
Analysis of the comparative workflow and performance characteristics of the VITEK 2 and Phoenix systems.
The VITEK 2 (bioMérieux, Marcy L'Etoile, France) and the Phoenix systems (BD Diagnostic Systems, Sparks, Md.) are automated instruments for rapid organism identification and susceptibility testing. We evaluated the workflow, the time to result, and the performance of identification and susceptibility testing of both instruments. A total of 307 fresh clinical isolates were tested: 141 Enterobact...
متن کاملEvaluation of the BD Phoenix automated microbiology system for identification and antimicrobial susceptibility testing of Enterobacteriaceae.
We evaluated the accuracy of the BD Phoenix system for the identification (ID) and antimicrobial susceptibility testing (AST) of 251 isolates of the family Enterobacteriaceae representing 31 species. Organisms were inoculated onto the Phoenix panel according to the manufacturer's instructions. The results from conventional biochemical tests were used for the reference method for ID. Agar diluti...
متن کاملOccurrence and Antimicrobial Resistance of Enterococcus spp. Isolated from Lettuce and Irrigation Water in Abidjan, Côte d\'Ivoire
Background: Enterococcus spp., belonging to the group of lactic acid bacteria, are Gram-positive ubiquitous commensals of the intestines of human beings as well as warm-blooded animals. The main objective of this study was to determine the occurrence and antimicrobial resistance of Enterococcus spp. isolated from lettuce and irrigation water in Abidjan, Côte d'Ivoire. Methods: A total of...
متن کاملPrevalence of amoxicillin resistance by Enterococci found in the hospital wastewater
Enterococci are found worldwide and are considered to be opportunistic pathogens. Antimicrobial resistance in these bacteria is increasing and is associated with their capability to sustain in the wastewater. We, therefore, aimed to determine the antimicrobial resistance of Enterococcus spp. that are isolated from the wastewater and clinical specimens. Isolation, identification, and de...
متن کاملPerformance of Vitek 2 for antimicrobial susceptibility testing of Staphylococcus spp. and Enterococcus spp.
Vitek 2 (bioMérieux, Inc., Durham, NC) is a widely used commercial antimicrobial susceptibility testing system. We compared MIC results obtained by Vitek 2 to those obtained by the Clinical and Laboratory Standards Institute (CLSI) broth microdilution (BMD) reference method for 134 staphylococcal and 84 enterococcal clinical isolates. Nineteen agents were evaluated, including all those availabl...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of clinical microbiology
دوره 41 3 شماره
صفحات -
تاریخ انتشار 2003