Experimental and Numerical Investigation of Airflow and Contaminant Transport in an Airliner Cabin Mockup

نویسندگان

  • Zhao Zhang
  • Xi Chen
  • Sagnik Mazumdar
  • Tengfei Zhang
  • Qingyan Chen
چکیده

The study of airflow and contaminant transport in airliner cabins is very important for creating a comfortable and healthy environment. This paper shows the results of such a study by conducting experimental measurements and numerical simulations of airflow and contaminant transport in a section of half occupied, twin-aisle cabin mockup. The air velocity and air temperature were measured by ultrasonic and omni-directional anemometers. A gaseous contaminant was simulated by a tracer gas, sulfur hexafluoride or SF6, and measured by a photoacoustic multi-gas analyzer. A particulate contaminant was simulated by 0.7 μm Di-Ethyl-HexylSebacat (DEHS) particles and measured by an optical particle sizer. The numerical simulations used the Reynolds averaged Navier-Stokes equations based on the RNG k-ε model to solve the air velocity, air temperature, and gas contaminant concentration; and employed a Lagrangian method to model the particle transport. The numerical results quantitatively agreed with the experimental data while some remarkable differences exist in airflow distributions. Both the experimental measurements and computer simulations were not free from errors. A complete and accurate validation for a complicated cabin environment is challenging and difficult.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Influence of cabin conditions on placement and response of contaminant detection sensors in a commercial aircraft.

Potential causalities due to airborne disease transmission and risk of chem-bio terrorism in commercial airliner cabins can be reduced by fast responses. Fast responses are only possible by using sensors at appropriate locations in the cabins. Cost, size and weight factors restrict the number of sensors that could be installed inside a cabin. Since release locations and seating patterns of pass...

متن کامل

A one-dimensional analytical model for airborne contaminant transport in airliner cabins.

UNLABELLED Quick information on airborne infectious disease transmission in airliner cabins is essential to reduce the risk of infection of passengers and crew members. This investigation proposed a one-dimensional analytical model that can predict the longitudinal transmission of airborne contaminants or disease viruses inside an airliner cabin. The model considered both diffusive and convecti...

متن کامل

Experimental studies of thermal environment and contaminant transport in a commercial aircraft cabin with gaspers on.

Gaspers installed in commercial airliner cabins are used to improve passengers' thermal comfort. To understand the impact of gasper airflow on the air quality in a cabin, this investigation measured the distributions of air velocity, air temperature, and gaseous contaminant concentration in five rows of the economy-class section of an MD-82 commercial aircraft. The gaseous contaminant was simul...

متن کامل

Airflow inside tunnel boring machine: A numerical study and an experimental verification

Knowledge of the airflow distribution inside a Tunnel Boring Machine (TBM) can create a safe working environment for workers and machinery. The airflow quality and the related mass flow rate in the ventilation system should be sufficient to dilute gases and remove dust inside the tunnel. In this work, airflow distribution in the single shield TBM tunnel was studied using computational fluid dyn...

متن کامل

Investigation on the performance of airliner cabin air filter throughout the lifetime usage

The supply air from the airliner ventilation system is a mixture of outside air and recirculated air that passes through a high efficiency particulate air (HEPA) filter. The effectiveness of two commercial-available airliner cabin air filters were investigated under the laboratory-based measurement due to the practical restriction of airliner cabin filter test during usage. The filtration effic...