Monitoring the Laryngeal Nerves During Thyroidectomy. Initial 115 Cases Experience.
نویسندگان
چکیده
The lesions of the laryngeal nerves, despite low incidence, are the most severe long term complications after thyroidectomy. Visualization after careful dissection of the recurrent laryngeal nerve (RLN) is now the golden standard among thyroid surgeons. We assessed traditional landmarks for the identification of RLN and anatomic high risk situation. The study also presented our initial experience using neuro monitoring of RLN (IONM) during surgery. The results show a recognizable Zuckerkandl tubercle in 162 of the 222 cases (72,97%). After dissection RLN was found posterior from TZ in 154 cases (95,06%) and lateral from TZ in 8 cases (4,93%). The identification of the Zuckerkandl tubercle is a useful landmark for RLN localization. As concerning high risk situations we found 2 non recurrent laryngeal nerves (both on the right side). Extra laryngeal ramification of RLN is an anatomical reality with significant incidence (23,8% in our study) and major surgical involvement. Extra laryngeal ramification of RLN occurs more often between the cross point with inferior thyroid artery and larynx entry point. Monitoring the branches of RLN we obtain major EMG signal on the anterior one. The surgical meaning is that the anterior branch carries the most important motor fibers and we have to pay extra care in the correct identification and preservation of it. From a total of 222 visually identified RLN we have 215 nerves (96,84%) with positive EMG signal on monitoring. For 7 nerves (3,15%) we had no EMG signal. In 3 cases (2 total thyroidectomies and 1 lobectomy) involving 5 RLN there was a false negative result caused by electrode malposition or desoldering from endotracheal tube. Our initial experience shows that IONM is harmless, easy to handle and a useful tool for identifying the nerve and confirm its integrity. More extended studies are needed to show if intraoperative monitoring decreases the rate of RLN iatrogenic injury.
منابع مشابه
Application experience of intraoperative neuromonitoring in thyroidectomy.
OBJECTIVE The aim of this study is to summarize the experience of intraoperative neuromonitoring system for monitoring and protection of recurrent laryngeal nerve during thyroid surgery. METHODS There were 220 cases in this study, male 53, female 167, mean age 38.2 years old. 85 cases in the study had thyroid cancer, 19 cases had thyroid benign tumor, 90 cases had thyroid goiter, 3 cases had ...
متن کاملAcute prediction of laryngeal outcome during thyroid surgery by electromyographic laryngeal monitoring.
BACKGROUND The purpose of this study was to evaluate the contribution of laryngeal intraoperative nerve monitoring (IONM) during thyroidectomy in predicting postoperative laryngeal mobility. METHODS Between 2009 and 2012, 127 patients underwent thyroidectomy, during which 216 recurrent laryngeal nerves were stimulated with suprathreshold stimulations. Laryngeal mobility was examined through d...
متن کاملExternal branch of the superior laryngeal nerve monitoring during thyroid and parathyroid surgery: International Neural Monitoring Study Group standards guideline statement.
UNLABELLED Intraoperative neural monitoring (IONM) during thyroid surgery has gained widespread acceptance as an adjunct to the gold standard of visual identification of the recurrent laryngeal nerve (RLN). Contrary to routine dissection of the RLN, most surgeons tend to avoid rather than routinely expose and identify the external branch of the superior laryngeal nerve (EBSLN) during thyroidect...
متن کاملProtection and Dissection of Recurrent Laryngeal Nerve in Salvage Thyroid Cancer Surgery to Patients with Insufficient Primary Operation Extent and Suspicious Residual Tumor.
Some thyroid cancer patients undergone insufficient tumor removal in the primary surgery in China . our aim is to evaluate the impact of dissection of the recurrent laryngeal nerve during a salvage thyroid cancer operation in these patients to prevent nerve injury. Clinical data of 49 enrolled patients who received a salvage thyroid operation were retrospectively reviewed. Primary pathology was...
متن کاملElectrophysiologic laryngeal nerve monitoring in high-risk thyroid surgery.
We recently began performing intraoperative electrophysiologic monitoring of the recurrent laryngeal nerve and the external branch of the superior laryngeal nerve during high-risk thyroidectomies. Neuromonitoring can detect stimulation of these nerves and thereby prevent a mechanical or thermal injury that can result in neurapraxia or axonotmesis. Monitoring is also useful during dissection in ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Chirurgia
دوره 110 4 شماره
صفحات -
تاریخ انتشار 2015