Improvement of elastographic displacement estimation using a two-step cross-correlation method.

نویسندگان

  • Hao Chen
  • Hairong Shi
  • Tomy Varghese
چکیده

The cross-correlation algorithm used to compute the local strain components for elastographic imaging requires a minimum radio-frequency data segment length of around 10 wavelengths to obtain accurate and precise strain estimates with a reasonable signal-to-noise ratio. Shorter radio-frequency data segments generally introduce increased estimation errors as the information content in the data segment reduces. However, shorter data segments and increased overlaps are essential to improve the axial resolution in the strain image. In this paper, we propose a two-step cross-correlation technique that enables the use of window lengths on the order of a single wavelength to provide displacement and strain estimates with similar noise properties as those obtained with a 10 wavelength window. The first processing step utilizes a window length on the order of 10 wavelengths to obtain coarse displacement estimates between the pre- and post-compression radio frequency data frames. This coarse displacement is then interpolated and utilized as the initial guess-estimate for the second cross-correlation processing step using the smaller window. This step utilizes a single wavelength window to improve the axial resolution in strain estimation, without significantly compromising the noise properties of the image. Simulation and experimental results show that the signal-to-noise and contrast-to-noise ratio estimates improve significantly at the smaller window lengths with the two-step processing when compared with the use of a similar sized window in the currently utilized single window method.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Corrections to the displacement estimation based on analytic minimization of adaptive regularized cost functions for ultrasound elastography.

Ultrasound elastography has been widely applied in clinical diagnosis. To produce high-quality elastograms, displacement estimation is important to generate ne displacement map from the original ratio-frequency signals. Traditional displacement estimation methods are based on the local information of signals pair, such as cross-correlation method, phase zero estimation. However, the tissue move...

متن کامل

Noise analysis and improvement of displacement vector estimation from angular displacements.

Elastography or elasticity imaging techniques typically image local strains or Young's modulus variations along the insonification direction. Recently, techniques that utilize angular displacement estimates obtained from multiple angular insonification of tissue have been reported. Angular displacement estimates obtained along different angular insonification directions have been utilized for s...

متن کامل

Analysis of a hybrid spectral strain estimation technique in elastography.

Conventional spectral elastographic techniques estimate strain using cross-correlation methods. Despite promising results, decorrelation effects compromise the accuracy of these techniques and, subsequently, the tissue strain estimates. Since tissue compression in the time-domain corresponds to upscaling in the frequency-domain, decorrelation effects become more pronounced as tissue strains inc...

متن کامل

Elastographic imaging using staggered strain estimates.

Conventional techniques in elastography estimate strain as the gradient of the displacement estimates obtained through crosscorrelation of pre- and postcompression rf A-lines. In these techniques, the displacements are estimated over overlapping windows and the strains are estimated as the gradient of the displacement estimates over adjacent windows. The large amount ofnoise at high window over...

متن کامل

Two-dimensional multi-level strain estimation for discontinuous tissue.

A large number of the strain estimation methods presented in the literature are based on the assumption of tissue continuity that establishes a continuous displacement field. However, in certain locations in the body such as the arteries in vivo scanning may produce displacement fields that are discontinuous between the two walls of the artery. Many of the displacement or strain estimators fail...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Ultrasound in medicine & biology

دوره 33 1  شماره 

صفحات  -

تاریخ انتشار 2007