Evaluation of calibration methods of a photometer measuring maritime light-emitting diode buoy lanterns
نویسندگان
چکیده
Erkki Ikonen Helsinki University of Technology Metrology Research Institute P.O. Box 3000 FIN-02015 HUT Finland Abstract. A photometer used for on-line product testing of light-emitting diode (LED) buoy lanterns is calibrated for illuminance responsivity using two different methods. The first method is based on absolute calibration of the photometer with the CIE standard illuminant A light source, combined with spectral correction factors (SCFs) calculated from the measured spectral responsivity of the photometer and relative spectra of the LED lanterns. The second method is based on direct comparison with a characterized reference photometer using the LED lanterns as light sources. Comparison of the resulting correction factors shows that both methods agree within 1%. However, the second method includes geometrical aspects and LED characteristics that caused problems. These problems are discussed and the reasons for recommending the first method are given. © 2004 Society of Photo-Optical Instrumentation Engineers. [DOI: 10.1117/1.1628245]
منابع مشابه
Evaluation of the Effect of Protective Sleeve on Output Intensity of Light Emitting Diode Light Cure Units
Aim: The purpose of this study was to compare the difference in the output intensity of Light Emitting Diode (LED) light cure (LC) devices with and without a protective sleeve and its clinical significance. Materials and Methods: The output intensity of 152 LC units in dental offices across the state of Odisha were examined. The collection of related information included an average number of e...
متن کاملComparative evaluation of the effect of Light Emitting Diode (LED) and Quartz Tungsten Halogen (QTH) light curing units on color stability of Filtek Z350 XT
Introduction:Discoloration of the resin-based composites is a common problem in restorative dentistry. There are many factors associated with the discoloration of dental materials in the oral environment. The purpose of this study was to evaluate the color changes in a nano-composite cured with a quartz-tungsten-halogen (QTH) and light emitting diode (LED) unit. Methods:80 disk-shaped specim...
متن کاملSimple, accurate solid-state diode photometer for use in measuring oxygen saturation of whole blood.
A small, easily-built photometer is described, in which a solid-state light-emitting diode is used as the light source and a phototransistor as the detector. The detector response is kept constant by modulating the diode intensity in proportion to the absorption characteristics of the sample being analyzed. Linearity and stability are good, even with turbid solutions (drift is <0.00 1 absorbanc...
متن کاملInvestigation of the Effect of Recombination on Superluminescent Light-Emitting Diode Output Power Based on Nitride Pyramid Quantum Dots
In this article, the temperature behavior of output power of superluminescent light-emitting diode (SLED) by considering the effect of non-radiative recombination coefficient, non-radiative spontaneous emission coefficient and Auger recombination coefficients has been investigated. For this aim, GaN pyramidal quantum dots were used as the active region. The numerical method has been used to sol...
متن کاملDesign, construction and calibration of single channel sun-photometer for study of aerosols
Aerosols are tiny liquid or solid particles suspended in the air have a strong influence on air quality, human health and climate change. Sun-photometer is a tool for measuring the optical and physical characteristics of aerosols by using sunlight at various wavelengths from the Earth surface. In this paper, the design, construction, and calibration of a single channel sun-photometer is present...
متن کامل