Identifying orthogonal and similar reversed phase liquid chromatography stationary phases using the system selectivity cube and the hydrophobic subtraction model.
نویسندگان
چکیده
We have compared over 500 RPLC columns characterized by the hydrophobic subtraction model using the system selectivity cube (SSC). We have shown numerous differences in column selectivity even among columns in the same class (e.g., alkyl-silica, cyano, or embedded polar groups). We also illustrate the utility of our method for selecting alternative columns with different selectivities for problematic separations and for selecting orthogonal columns for use in two-dimensional separations. The system selectivity cube offers a visual way to easily compare many columns simultaneously and select those columns offering the desired selectivity.
منابع مشابه
EFFECTS OF TEMPERATURE AND PERCENTAGE OF ORGANIC MODIFIER ON RETENTION AND SELECTIVITY IN RP-HPLC USING SOLVATION PARAMETER MODEL
Effects of temperature and percentage of organic modifier were studied on retention and selectivity in RP-HPLC using solvation parameter model. The system constants were determined by multiple linear regression analysis from experimental values in the retention factor for a group of different solutes with known descriptors by computer using the program SPSS/PC. The experimental results showed t...
متن کاملPerformance of 2-Amino Tetraphenyl Porphyrin as Stationary Phase in RP-HPLC of Amino Acids
The search for new stationary phases has been one of the predominant concerns in high performance liquid chromatography (HPLC) in order to achieve better resolutions, longer column lives, and reduce the time of analysis. A chromatographic packing for separation of underivatized amino acids (AAs) were prepared by dynamically coating 2-amino tetraphenyl prophyrin (atpp) on a C-18 reversed-pha...
متن کاملEVALUATION OF THE USE OF ANIONIC/ NONIONIC MIXED MICELLES IN REVERSED PHASE LIQUID CHROMATOGRAPHY OF CHLOROPHENOLS
The use of aqueous mixed micellar system consisting of sodium dodecyl sulfate (SDS) and polyoxyethylene (23) dodecanol (Brij-35) as the mobile phase in reversed-phase liquid chromatography was studied. A group of chlorophenols was used as the test mixture. Adding organic modifier to the system showed that the use of low concentrations of organic additives improves efficiency in SDS/Brij-35 mixe...
متن کاملSeparation of Somatropin and Its Degradation Products by High-Performance Liquid Chromatography Using a Reversed-Phase Polymeric Column
The accurate prediction of protein stability is one of the most challenging goals in protein formulation and delivery. In this study, a gradient RP-HPLC method is described for the separation of human growth hormone (hGH) variants as deamidated and oxidized forms. The methodology employed a polymeric poly (styrene-co-divinylbenzene) column and a 1mL/min flow rate of a linear gradient of 0.1% v/...
متن کاملSeparation of Somatropin and Its Degradation Products by High-Performance Liquid Chromatography Using a Reversed-Phase Polymeric Column
The accurate prediction of protein stability is one of the most challenging goals in protein formulation and delivery. In this study, a gradient RP-HPLC method is described for the separation of human growth hormone (hGH) variants as deamidated and oxidized forms. The methodology employed a polymeric poly (styrene-co-divinylbenzene) column and a 1mL/min flow rate of a linear gradient of 0.1% v/...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of chromatography. A
دوره 1249 شماره
صفحات -
تاریخ انتشار 2012