Radiolucent lines in low-contact-stress mobile-bearing total knee arthroplasty: a blinded and matched case control study

نویسندگان

  • Patrick Sadoghi
  • Andreas Leithner
  • Patrick Weber
  • Jörg Friesenbichler
  • Gerald Gruber
  • Norbert Kastner
  • Katrin Pohlmann
  • Volkmar Jansson
  • Bernd Wegener
چکیده

BACKGROUND Low-contact-stress (LCS) mobile-bearing total knee arthroplasty (TKA) (Johnson & Johnson, New Brunswick, NJ; previously: DePuy, Warsawa, USA) provides excellent functional results and wear rates in long-term follow-up analyses. Radiological analysis shows radiolucent lines (RLL) appearing immediately or two years after primary implantation, indicative of poor seat. Investigations proved RLL to be more frequent in uncemented TKA, resulting in a consensus to cement the tibial plateau, but their association with clinical findings and patients discomfort and knee pain is still unknown. METHODS 553 patients with 566 low-contact-stress (LCS) total knee prostheses were screened for continuous moderate knee pain. We compared tibial stress shielding classified by Ewald in patients suffering from pain with a matched, pain-free control group on blinded X-rays. We hypothesized a positive correlation between pain and radiolucency and higher frequency of such radiolucent lines in the most medial and most lateral zones of the tibial plateau. RESULTS Twenty-eight patients suffered from knee pain in total. Radiolucencies were detected in 27 of these cases and in six out of 28 matched controls without knee pain. We could demonstrate a significant correlation of knee pain and radiolucencies, which appeared significantly more frequently in the outermost zones of the tibial plateau. CONCLUSION Our findings suggest that radiolucent lines, representing poor implant seat, about the tibial plateau are associated with knee pain in LCS patients. Radiolucencies are observed more often in noncemented LCS, and cementing the tibial plateau might improve implant seat and reduce both radiolucent lines and associated knee pain.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Comparison of the Clinical and Radiographic Results of Press Fit Condylar Rotating-Platform High-Flexion and Low Contact Stress Mobile Bearing Prosthesis in Total Knee Arthroplasty: Short term Results

PURPOSE This study compared the results of rotating-platform high-flexion (RP-F) total knee arthroplasty with low contact stress (LCS) for clinical and radiographical assessment after a short-term period. MATERIALS AND METHODS 68 total knee arthroplasties using a RP-F and LCS system were analyzed retrospectively. Thirty-five of the 68 were osteoarthritic knees and were followed-up for more th...

متن کامل

Low-Contact-Stress Knee Arthroplasty: Past History or Ahead of Time?

Low-contact-stress mobile-bearing (MB) total knee arthroplasty (TKA) can rely on a long history. Its concept comprises a combination of high condylar congruency and compensatory bearing rotation to promote load sharing. However, other MB designs have become available, and critical points have been raised about the benefit of MB in general. Although there is kinematic and kinetic support for the...

متن کامل

Dissociation of mobile-bearing patellar component in low contact stress patellofemoral arthroplasty, its mechanism and management: two case reports

INTRODUCTION Isolated patellofemoral osteoarthritis can be treated with patellofemoral arthroplasty. CASE PRESENTATION We present two cases of isolated patellofemoral osteoarthritis treated with Low Contact Stress patellofemoral arthroplasty; in both cases the polyethylene mobile-bearing of the patellar component dissociated from the metal backing. One patient had a revision to a Richards pat...

متن کامل

Patellar polyethylene spinout after low-contact stress, high-congruity, mobile-bearing patellofemoral arthroplasty.

A low-contact stress, high-congruity, mobile-bearing patellofemoral joint arthroplasty decreases the contact force in the patellofemoral joint, theoretically reducing patellar polyethylene wear and increasing implant longevity. This article describes the case of a 47-year-old obese woman who presented with pain and loss of extension after a low-contact stress, high-congruity, mobile-bearing pat...

متن کامل

Polished Cobalt-Chrome vs Titanium Tibial Trays in Total Knee Replacement (a Comparison using the PFC Sigma System)

Fixed-bearing total knee arthroplasty components can cause wear debris due to fretting micromotion between the polyethylene insert and the metal tibial tray, possibly leading to osteolysis and implant failure. This study compared the effects of either a highly polished cobalt-chrome (CoCr) or titanium tibial tray in patients receiving the PFC. Sigma® posterior stabilized knee system with a mode...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 12  شماره 

صفحات  -

تاریخ انتشار 2011