Does Postoperative Mechanical Axis Alignment Have an Effect on Clinical Outcome of Primary Total Knee Arthroplasty? A Retrospective Cohort Study

نویسندگان

  • Mikhail Salzmann
  • Peter Fennema
  • Roland Becker
  • Hagen Hommel
چکیده

Background There is an ongoing debate whether patients with constitutional varus should be restored to neutral mechanical alignment following total knee arthroplasty (TKA). Objective The aim of this retrospective cohort study is to determine whether mild unintentional postoperative varus alignment (3°-6°) influences TKA outcome in patients with and without preoperative varus alignment due to medial osteoarthritis of the knee. Methods We analyzed 172 consecutive TKA cases between April 2011 and May 2014. Patients were divided into four groups based on their preoperative and postoperative hip-knee-ankle angles (HKA): preoperative varus ≤ 3° with postoperative varus position ≤ 3° (Group 1, n = 47); preoperative varus >3° with postoperative varus ≤ 3° (Group 2, n = 104); preoperative varus ≤ 3° with postoperative varus malalignment > 3° (Group 3, n = 3); and preoperative varus > 3° with postoperative varus malalignment > 3° (Group 4, n = 18). Patients were followed up until 2 years postoperatively. Results Knee Society Score and Western Ontario and McMaster University Osteoarthritis Index scores for all study groups increased following TKA, with no postoperative differences at any time point. Group 4 performed significantly better on the Forgotten Joint Score than Group 2 (p = 0.019). Group 4 performed significantly better on the High Flexion Knee Score than Group 2 (p = 0.004) and Group 1 (p = 0.019). All other between-group differences were not statistically significant. Conclusion Residual postoperative varus alignment of the lower limb does not appear to adversely affect clinical outcome following TKA for varus-type osteoarthritis.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Restoration of the Mechanical Axis in Total Knee Artrhoplasty Using Patient-Matched Technology Cutting Blocks. A Retrospective Study of 132 Cases

Background: The aim of this study is to evaluate the accuracy of bone cuts and the resultant alignment, using theMyKnee patient specific cutting blocks.Methods: We retrospectively reviewed 132 patients undergoing primary TKR for osteoarthritis by one single surgeon.The operative time, the preoperative Hip-Knee-Ankle (HKA) axis based on the CT-scan, the postoperative HKA axisbased on long axis s...

متن کامل

The Effect of Total Knee Arthroplasty on Hindfoot Alignment in Patients with Severe Genu Varum and Genu Valgum

Background: The maintenance of deformity in the ankle and hindfoot after correction of knee deformity following kneearthroplasty may cause abnormal tension in the knee and patient dissatisfaction. The aim of this study was to determinethe effect of knee arthroplasty on the hindfoot alignment in patients with severe genu varum and valgum.Methods: A total of 84 patients with pri...

متن کامل

The Effect of Sagittal Femoral Bowing on the Femoral Component Position in Total Knee Arthroplasty

Background: In the current study, we investigated that how sagittal femoral bowing can affect the sagittal alignment ofthe femoral component in total knee arthroplasty (TKA).Methods: There were 25 patients underwent TKA. Long leg radiography in lateral view was performed. The sagittalfemoral bowing (SFB) and component alignment in relation to the sagittal mechanical axis and distal anterior cor...

متن کامل

Comparison of Clinical, Functional, and Radiological Outcomes of Total Knee Arthroplasty Using Conventional and Patient-Specific Instrumentation

Background: Recently, patient-specific instrumentation (PSI) systems have been developed in order to increase theaccuracy of component positioning during total knee arthroplasty (TKA); however, the findings of previous studies arecontroversial in this regard. In the current randomized clinical study, the outcomes of computer tomography (CT)-basedPS (patient specific)-guided TK...

متن کامل

Moderate varus/valgus malalignment after total knee arthroplasty has little effect on knee function or muscle strength.

BACKGROUND AND PURPOSE Postoperative muscle strength and component alignment are important factors affecting functional results after total knee arthroplasty (TKA). We are not aware of any studies that have investigated the relationship between them. We therefore investigated whether coronal malalignment of the mechanical axis and/or of individual implant components would affect knee muscle str...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 11  شماره 

صفحات  -

تاریخ انتشار 2017