Long-term performance of ceramic and metal femoral heads on conventional polyethylene in young and active patients: a matched-pair analysis.
نویسندگان
چکیده
BACKGROUND Ceramic femoral heads produce less wear of the opposing polyethylene than do metal femoral heads in wear simulation studies. This is a matched-pair analysis of the wear of ceramic and metal femoral heads on conventional polyethylene in uncemented total hip replacements in young, active patients at a minimum of fifteen years of follow-up. METHODS From June 1989 to May 1992, thirty-one matched pairs of alumina ceramic or cobalt-chromium metal femoral heads were identified. Patients were matched on the basis of age, sex, body weight, diagnosis, and activity level. The mean age was 55 ± 9 years (range, twenty-three to sixty-five years) at the time of surgery. All procedures were performed with a posterolateral surgical approach by a single surgeon using press-fit Ranawat-Bernstein femoral stems, Harris-Galante-II acetabular cups, GUR 4150 conventional polyethylene (sterilized in argon), and 28-mm-diameter femoral heads. Wear measurements were performed by two independent observers using the computer-assisted Roman software. RESULTS The average duration of follow-up was 17 ± 1.7 years (range, fifteen to twenty years). The mean Hospital for Special Surgery hip scores (and standard deviation) in the ceramic and metal groups were 39 ± 4 and 40 ± 3 at the time of final follow-up. The University of California Los Angeles activity score at the time of the final follow-up was 6 ± 2 for both groups. The mean wear rates for the ceramic group and the metal group were 0.086 ± 0.05 mm/yr and 0.137 ± 0.05 mm/yr, respectively (p = 0.0015). There was one reoperation in the ceramic group because of distal femoral osteolysis. There were three failures in the metal group, requiring isolated liner exchange in two hips and revision of the acetabular component in one hip because of wear-induced osteolysis and/or loosening that caused symptoms. Five hips in the ceramic group and six hips in the metal group had radiographic evidence of acetabular or femoral osteolysis, but none were symptomatic. CONCLUSIONS Ceramic femoral heads produced significantly less wear on conventional polyethylene liners at the time of long-term follow-up than did metal heads in this matched-pair analysis of young and active patients with uncemented fixation.
منابع مشابه
Long-term durability of alumina ceramic heads in THA
BACKGROUND The optimal type of bearing for hip arthroplasty remains a matter of debate. Ceramic-on-polyethylene (CoP) bearings are frequently used in younger and more active patients to reduce wear and increase biocompatibility compared to Metal-on-Polyethylene (MoP) bearings. However, in comparison to metal heads, the fracture risk of ceramic heads is higher. In addition, ceramic head fracture...
متن کاملLarge ceramic femoral heads: what problems do they solve?
Large ceramic femoral heads offer several advantages that are potentially advantageous to patients undergoing both primary and revision total hip replacement. Many high-quality studies have demonstrated the benefit of large femoral heads in reducing post-operative instability. Ceramic femoral heads may also offer an advantage in reducing polyethylene wear that has been reported in vitro and is ...
متن کاملComparison of in vivo wear between polyethylene liners articulating with ceramic and cobalt-chrome femoral heads.
At yearly intervals we compared the radiological wear characteristics of 81 alumina ceramic femoral heads with a well-matched group of 43 cobalt-chrome femoral heads. Using a computer-assisted measurement system we assessed two-dimensional penetration of the head into the polyethylene liner. We used linear regression analysis of temporal data of the penetration of the head to calculate the true...
متن کاملDoes Metal Transfer Differ on Retrieved Ceramic and CoCr Femoral Heads?
Metal transfer has been observed on retrieved THA femoral heads for both CoCr and ceramic bearing materials. In vitro wear testing has shown increased wear to polyethylene acetabular liners with the presence of metal transfer. This study sought to investigate the extent of metal transfer on the bearing surface of CoCr and ceramic femoral heads and identify prevalent morphologies. Three bearing ...
متن کاملWear of Highly Cross-linked Polyethylene against Cobalt Chrome and Ceramic Femoral Heads
+*Jennings, L M; *Galvin, A L; *Fisher J +Institute of Medical & Biological Engineering, Leeds, UK [email protected] Introduction There is increasing interest in the coupling of highly cross-linked polyethylene with large diameter heads in the hip, due to the reported lower wear characteristics of highly cross-linked polyethylene compared to conventional polyethylene [1, 2, 3]. Further, ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Journal of bone and joint surgery. American volume
دوره 95 13 شماره
صفحات -
تاریخ انتشار 2013