Effect of Aerosol Devices and Administration Techniques on Drug Delivery in a Simulated Spontaneously Breathing Pediatric Tracheostomy Model.
نویسندگان
چکیده
BACKGROUND This study was conducted to compare the efficiency of jet nebulizers, vibrating mesh nebulizers, and pressurized metered-dose inhalers (pMDI) during assisted and unassisted administration techniques using a simulated spontaneously breathing pediatric model with a tracheostomy tube (TT). METHODS An in vitro breathing model consisting of an uncuffed TT (4.5-mm inner diameter) was attached to a collecting filter (Respirgard) connected to a dual-chamber test lung and a ventilator (Hamilton Medical) to simulate breathing parameters of a 2-y-old child (breathing frequency, 25 breaths/min; tidal volume, 150 mL; inspiratory time, 0.8 s; peak inspiratory flow, 20 L/min). Albuterol sulfate was administered using a jet nebulizer (MicroMist, 2.5 mg/3 mL), vibrating mesh nebulizer (Aeroneb Solo, 2.5 mg/3 mL), and pMDI (ProAir HFA, 432 μg). Each device was tested 5 times with an unassisted technique (direct administration of aerosols with simulated spontaneous breathing) and with an assisted technique (using a manual resuscitation bag in conjunction with an aerosol device and synchronized with inspiration). Drug collected on the filter was analyzed by spectrophotometry. RESULTS With the unassisted technique, the pMDI had the highest inhaled mass percent (IM%, 47.15 ± 7.82%), followed by the vibrating mesh nebulizer (19.77 ± 2.99%) and the jet nebulizer (5.88 ± 0.77%, P = .002). IM was greater with the vibrating mesh nebulizer (0.49 ± .07 mg) than with the pMDI (0.20 ± 0.03 mg) and the jet nebulizer (0.15 ± 0.01 mg, P = .007). The trend of lower deposition with the assisted versus unassisted technique was not significant for the jet nebulizer (P = .46), vibrating mesh nebulizer (P = .19), and pMDI (P = .64). CONCLUSIONS In this in vitro pediatric breathing model with a TT, the pMDI delivered the highest IM%, whereas the vibrating mesh nebulizer delivered the highest IM. The jet nebulizer was the least efficient device. Delivery efficiency was similar with unassisted and assisted administration techniques.
منابع مشابه
The Effect of Aerosol Devices and Administration Techniques on Drug Delivery in a Simulated Spontaneously Breathing Pediatric Model with a Tracheostomy
Background: Evidence on aerosol delivery via tracheostomy is lacking. The purpose of this study was to evaluate the effect of aerosol device and administration technique on drug delivery in a simulated spontaneously breathing pediatric model with tracheostomy. Methods: Delivery efficiencies during spontaneous breathing with assisted and unassisted administration techniques were compared using t...
متن کاملNebulized albuterol delivery in a model of spontaneously breathing children with tracheostomy.
BACKGROUND Nebulized therapy is commonly used in spontaneously breathing tracheostomized patients, despite a lack of recommended devices and techniques. I compared albuterol dose delivered to a model of spontaneously breathing children with tracheostomy, using different nebulizers, tracheostomy tube sizes, inhalation techniques, and breathing patterns. METHODS A tracheostomy model was connect...
متن کاملQuantifying Aerosol Delivery in Simulated Spontaneously Breathing Patients With Tracheostomy Using Different Humidification Systems With or Without Exhaled Humidity.
BACKGROUND Aerosol and humidification therapy are used in long-term airway management of critically ill patients with a tracheostomy. The purpose of this study was to determine delivery efficiency of jet and mesh nebulizers combined with different humidification systems in a model of a spontaneously breathing tracheotomized adult with or without exhaled heated humidity. METHODS An in vitro mo...
متن کاملComparison of HFNC, bubble CPAP and SiPAP on aerosol delivery in neonates: An in-vitro study.
UNLABELLED Aerosol drug delivery via high flow nasal cannula (HFNC), bubble continuous positive airway pressure (CPAP), and synchronized inspiratory positive airway pressure (SiPAP) has not been quantified in spontaneously breathing premature infants. OBJECTIVES The purpose of this study was to compare aerosol delivery via HFNC, bubble CPAP, and SiPAP in a model of a simulated spontaneously b...
متن کاملPerformance Comparisons of Jet and Mesh Nebulizers Using Different Interfaces in Simulated Spontaneously Breathing Adults and Children.
BACKGROUND Different types of nebulizers and interfaces are used for the treatment of adults and children with pulmonary diseases. The purpose of this study was to determine the efficiency of a mesh nebulizer (MN) with a proprietary adapter and a jet nebulizer (JN) under different configurations in adult and pediatric models of spontaneous breathing. We hypothesize that delivery efficiency of J...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Respiratory care
دوره 60 7 شماره
صفحات -
تاریخ انتشار 2015