Accuracy of third-order bends of nickel-titanium wires and the effect of high and low pressure during memorizing heat treatment.

نویسندگان

  • Thomas Stamm
  • Ariane Hohoff
  • Dirk Wiechmann
  • Jan Sütfeld
  • Dirk Helm
چکیده

This study evaluated the accuracy of third-order bends of nickel-titanium wires and determined the effect of high and low pressure for maintaining the wire shape during memorizing heat treatment. A computer-aided bending machine was used to incorporate 200 randomly determined torsional angles between 0 degrees and 60 degrees into 30 linear 0.016 x 0.022-in NeoSentalloy F80 (GAC International, Central Islip, NY) wires. The torsional bendings were randomized into 2 groups. Bends assigned to group 1 (n = 100) received heat treatment of 1.6 MPa (16 bar) pressure, and bends assigned to group 2 (n = 100) received heat treatment of 50 MPa (500 bar) pressure. Cross-sectional cuts from the bent wires were prepared by using standard metallurgical techniques, and the torsional angles were analyzed under computer control. The results of our study show that third-order bends 30 degrees but 40 degrees , the bending error with both methods is clinically unacceptable. In addition to the variability in the dimension and composition of nickel-titanium wires, the scale of the incorporated plastic deformations makes a substantial contribution to the bending error. As far as permitted by the clinical situation, then, the bend should be distributed over the maximum possible wire length. Third-order bends in the first rectangular pseudoelastic nickel-titanium wires represent an efficient means of effecting torque at an early stage. This individualization allows the full therapeutic potential of these archwires to be exploited right from the initial phase of treatment.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A review of the requirements and hazards of toxic metals from orthodontic wires

Background: Orthodontics is a part of dentistry that includes preventive methods and correction of dental irregularities that need to be repositioned by functional and mechanical tools to provide an ideal occlusion and a beautiful face for patients. There are currently four metal arch wires used in orthodontic treatment: stainless steel alloy, cobalt-chromium alloy, nickel-titanium alloy, and b...

متن کامل

Effect of Overage Hardening Heat Treatment on the Micro Structure and Hardness of Nickel-based Super Alloy Rene-80

Rene-80 nickel-base superalloy as an alloy for production of the jet turbine blades shows high mechanical properties as well as microstructure stability during the high temperature engine operation. In this research, age hardening heat treatment cycle was done on the as-cast Rene-80 superalloy. In the following, microstructure, elemental analysis of phases and macro-hardness of the alloy before...

متن کامل

Effects of three different mouthwashes on the surface characteristics of nickel-titanium and Stainless steel archwires in orthodontics

Introduction: Patients are recommended regular using of mouthwashes to control dental caries or periodontal diseases since orthodontic treatment may have detrimental effects on the tooth structures. However, chemical agents may potentially damage metal components of orthodontic appliances. The aim of this study was to evaluate the influence of three mouthwashes on the surface characteristics of...

متن کامل

Effect of Inserting Coiled Wires in Tubes on the Fluid Flow and Heat Transfer Performance of Nanofluids

In the present study, numerical study of Al2O3-water nanofluid flow in different coiled wire inserted tubes are performed to investigate the effects of inserting coiled wires in tubes on the fluid dynamic and heat transfer performance ofv nanofluids. The numerical simulations of nanofluids are performed using two phase mixture model. The flow regime and the wall boundary conditions are assumed ...

متن کامل

An evaluation of two types of nickel-titanium wires in terms of micromorphology and nickel ions’ release following oral environment exposure

BACKGROUND This study aimed to compare superelastic and heat-activated nickel-titanium orthodontic wires' surface morphology and potential release of nickel ions following exposure to oral environment conditions. METHODS Twenty-four 20-mm-length distal cuts of superelastic (NiTi Force I®) and 24 20-mm-length distal cuts of heat-activated (Therma-Ti Lite®) nickel-titanium wires (American Ortho...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • American journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics

دوره 126 4  شماره 

صفحات  -

تاریخ انتشار 2004