Obesity and treatment of prostate cancer: what is the right dose of Lupron Depot?
نویسندگان
چکیده
To the Editors: The January 1, 2007, issue of Clinical Cancer Research includes a retrospective analysis by Dr. Smith of two previously reported prospective studies of gonadotropinreleasing hormone agonist treatment in men with locally advanced or recurrent nonmetastatic prostate cancer (1). It was concluded that despite lower pretreatment serum testosterone levels, obese men have higher total and free testosterone levels during treatment with leuprolide than men with normal body mass indices. These results raise the possibility that higher sex steroid levels during gonadotropin-releasing hormone agonist treatment contribute to greater prostate cancer mortality in obese men. It is notable that all the study subjects received the same dose of leuprolide 3-month depot (22.5 mg i.m. every 12 weeks; Lupron Depot, TAP Pharmaceuticals, Inc.) irrespective of their body mass index. Because of the use of a fixed dose of leuprolide irrespective of the body mass index, the conclusion of a causal relationship between obesity and inferior response to treatment with gonadotropin-releasing hormone agonist is open to debate. Lupron is a synthetic agonist analogue of gonadotropinreleasing hormone. The active form leuprorelin is a peptide and only parenteral forms are biologically active. In the sustained-release depot formulations, the hydrophilic leuprorelin is entrapped in biodegradable highly lipophilic synthetic polymer microspheres. The peptide drug is released from these depot formulations at a functionally constant daily rate for 1, 3, or 4 months, depending on the polymer type, with doses ranging between 3.75 and 30 mg (2). After injection into the intramuscular space, the lipophilic synthetic polymer microspheres are slowly degraded by enzymatic breakdown to release the biologically active hydrophilic peptide. Being hydrophilic, the peptide form remains confined to the extracellular fluid compartment, keeping its volume of distribution (f27 L) almost constant irrespective of the body weight. Hence, a fixed dose of Lupron has been assumed to be adequate for all study subjects. However, the half-life of a drug in a depot preparation not only depends on the volume of distribution of the active drug, but also on the rate of release of the active drug from its depot formulation. It is possible that the lipophilic depot injection forms a larger area of drug depot in obese subjects due to the increased amounts of adipose tissue in the muscles. This would result in more of the polymer microspheres being exposed to enzymatic breakdown. In this case, the rate of release of leuprorelin peptide from the polymer microspheres will be higher, thereby emptying the depot site of the drug before the 3month period. In Dr. Smith’s study subjects, the serum testosterone levels were obtained at 3 months, just prior to the end of the depot period. If serum testosterone was found to be elevated, could it have been because the depot preparation in the obese subjects emptied of the active peptide form earlier than in the nonobese subjects, resulting in suboptimal leuprorelin levels? This concern about body mass index having an effect on the depot preparation of Lupron has been shared by other investigators as evidenced by their use of different doses of Lupron in their patients with respect to the body weight (3–5). As to the effect of obesity on the drug efficacy of gonadotropinreleasing hormone agonists, further studies with simultaneous measurements of serum testosterone and plasma levels of the biologically active peptide form of the drug (leuprorelin) will be needed to clarify this important issue.
منابع مشابه
Step-and-Shoot versus Compensator-based IMRT: Calculation and Comparison of Integral Dose in Non-tumoral and Target Organs in Prostate Cancer
Introduction Intensity-Modulated Radiotherapy (IMRT) is becoming an increasingly routine treatment method. IMRT can be delivered by use of conventional Multileaf Collimators (MLCs) and/or physical compensators. One of the most important factors in selecting an appropriate IMRT technique is integral dose. Integral dose is equal to the mean energy deposited in the total irradiated volume of the p...
متن کاملAssessment of absorbed dose uncertainty of prostate due to source relocating in brachytherapy by monte carlo method
Brachytherapy, is a method to treat prostate cancer in which a radiation source is placed inside or next to the cancer affected tissues. Purpose of this article is to determine the uncertainty level of received dose in prostate tissue due to the relocation of the placed radiation sources and inflation in prostate after positioning the radiation seeds. To simulate the model 6711 Amersham (activi...
متن کاملAnalysis of Hip Joint Dose in Prostate Cancer Radiation Therapy: A Dosimetric Comparison of Treatment Plans
Background and purpose: Radiation therapy as a part of cancer treatment is used in almost 50-60% of involved cases. In prostate cancer radiation therapy, a large volume of pelvis is irradiated, so, it is necessary to preserve sensitive organs around the treatment area, especially rectum and bladder. In this study, some dosimetric parameters such as minimum dose (Dmin), maximum dose (Dmax), mean...
متن کاملDosimetric Comparison of Various Radiotherapeutic Treatment Plans Using Cobalt-60 and Linac for Prostate Cancer
Introduction: This study was designed to evaluate dosimetric parameters such as rectal dose, bladder dose, integral dose (ID), homogeneity index (HI) and conformity index (CI) in various treatment plans for prostate cancer. Materials and Methods: Pelvic computed tomography (CT) scans of 27 patients were acquired and transferred to the RTDosePLAN treatment planning system. For each patient, 8 co...
متن کاملAccuracy of the dose delivery in prostate cancer patients-using an electronic portal imaging device (EPID)
Background: To correct patient positioning errors (setup errors) during prostate cancer treatment using EPID and fiducial gold markers, to improve the accuracy of the dose delivery in these patients. Materials and Methods: Fifteen patients with localized prostate carcinoma after implantation of fiducial gold markers in their prostate gland underwent the five-field IMRT planning technique. The p...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical cancer research : an official journal of the American Association for Cancer Research
دوره 13 13 شماره
صفحات -
تاریخ انتشار 2007