A study of X-ray emission from laboratory sparks in air at atmospheric pressure

نویسندگان

  • J. R. Dwyer
  • Z. Saleh
  • H. K. Rassoul
  • D. Concha
  • M. Rahman
  • V. Cooray
  • J. Jerauld
  • M. A. Uman
  • V. A. Rakov
چکیده

[1] We present a detailed investigation of X-ray emission from long laboratory sparks in air at atmospheric pressure. We studied 231 sparks of both polarities using a 1-MV Marx generator with gap lengths ranging from 10 to 140 cm. The X rays generated by the discharges were measured using five NaI/PMT detectors plus one plastic scintillator/PMT detector, all enclosed in 0.32-cm-thick aluminum boxes. X-ray emission was observed to accompany about 70% of negative polarity sparks and about 10% of positive polarity sparks. For the negative sparks, X-ray emission was observed to occur at two distinct times during the discharge: (1) near the peak voltage, specifically, about 1 ms before the voltage across the gap collapsed, and (2) near the time of the peak current through the gap, during the gap voltage collapse. Using collimators we determined that the former emission emanated from the gap, while the latter appeared to originate from above the gap in the space over the high-voltage components. During individual sparks, the total energy of the X rays that was deposited in a single detector sometimes exceeded 50 MeV, and the maximum energy of individual photons in some cases exceeded 300 keV. X-ray emission near the peak voltage was observed for a wide range of electrode geometries, including 12-cm-diameter spherical electrodes, a result suggesting that the X-ray emission was the result of processes occurring within the air gap and not just due to high electric fields at the electrode.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Road Traffic and PM10, PM2.5 Emission at an Urban Area in Algeria: Identification and Statistical Analysis

Air quality in greater Algiers, in Algeria was assessed analyzing aerosol particulate matter (PM10 and PM2.5) at a site influenced by heavy road traffic. Particulate matters were collected using a Gent sampler to characterize the atmospheric aerosol of Algiers. An Energy dispersive X ray spectrometer (EDXRF) was used to determine the heavy metal concentrations in the PM2.5 and PM10 size fractio...

متن کامل

Road Traffic and PM10, PM2.5 Emission at an Urban Area in Algeria: Identification and Statistical Analysis

Air quality in greater Algiers, in Algeria was assessed analyzing aerosol particulate matter (PM10 and PM2.5) at a site influenced by heavy road traffic. Particulate matters were collected using a Gent sampler to characterize the atmospheric aerosol of Algiers. An Energy dispersive X ray spectrometer (EDXRF) was used to determine the heavy metal concentrations in the PM2.5 and PM10 size fractio...

متن کامل

An Experimental and Theoretical Study of the Effects of Excess Air Ratio and Waste Gate Opening Pressure Threshold on Nox Emission and Performance in a Turbocharged CNG SI Engine

Turbocharged CNG engines produce high NOx emission due to the fuel type and high combustion temperature. In this research, the effects of lean-burn and waste gate opening pressure threshold on NOx emission are studied theoretically and experimentally at WOT condition as well as 13-mode ECE-R49 test cycle. A code is developed in MATLAB environment for predicting engine NOx and the results are va...

متن کامل

Emission spectroscopy of a microhollow cathode discharge plasma in helium-water gas mixtures

Related Articles Convoluted effect of laser fluence and pulse duration on the property of a nanosecond laser-induced plasma into an argon ambient gas at the atmospheric pressure J. Appl. Phys. 113, 013304 (2013) Developing the model of laser ablation by considering the interplay between emission and expansion of aluminum plasma Phys. Plasmas 20, 013301 (2013) X-ray emission from a nanosecond-pu...

متن کامل

مقایسه گسیل یونی و پرتوی ایکس سخت بین نیتروژن و آرگون در دستگاه پلاسمای کانونی نوع مدر

In this study, some characteristics of a Mather type Plasma Focus (PF) device such as a discharge current, pinch time, ion flux and hard x-ray intensity has been investigated simultaneously in argon and nitrogen gases separately for various operating gas pressures and charging voltages of capacitor bank. It was observed that pinch phenomena was energy and pressure dependent in current sheath as...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008