Accuracy of an automated blood pressure device in stable inpatients: optimum vs routine use.

نویسندگان

  • C L Shuler
  • N Allison
  • S Holcomb
  • M Harlan
  • J McNeill
  • G Robinett
  • S P Bagby
چکیده

BACKGROUND Despite widespread use of the automated blood pressure (BP) device (IVAC model 4200, IVAC Corporation, San Diego, Calif), there is little formal validation in the literature on its accuracy. OBJECTIVE To assess the accuracy of the IVAC 4200 device, both under standardized conditions and as routinely used by ward staff, compared with the true indirect BP measured by mercury manometer (MM). METHODS One hundred forty-five stable inpatients were randomly selected for BP measurements by 3 randomly ordered protocols: (1) MM performed by certified investigators, (2) IVAC 4200 BP performed by trained investigators (research automated [RA]), and (3) IVAC 4200 BP performed by ward personnel (ward automated [WA]). RESULTS For RA compared with MM ("true" indirect BP), 59% of systolic and 54% of diastolic readings were within 5 mm Hg and 83% of systolic and 86% of diastolic were within 10 mm Hg for a British Hypertension Society grade C for both. For WA compared with MM, 40% of systolic and 50% of diastolic readings were within 5 mm Hg and 70% of systolic and 80% of diastolic readings were within 10 mm Hg for British Hypertension Society grades D and C, respectively. The presence of arrhythmias and/or low K5 values (fifth phase of Korotkoff sounds <30 mm Hg) significantly increased the inaccuracy for diastolic values. Inappropriate cuff selection significantly increased inaccuracy of systolic BP (WA vs MM). CONCLUSIONS The IVAC 4200 yields substandard estimates of systolic and diastolic BP even under standardized, thus optimum conditions. The presence of arrhythmias or low K5 values and the selection of inappropriate cuff size by the ward staff also contributed to inaccuracy.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

مقایسه اندازه گیری فشارخون توسط گوشی معمولی با گوشی تلفیقی

Background and Purpose: Blood pressure (BP) is routinely evaluated intermittently during the clinical status for care and treatment. The most common method to measure BP is by using the sphygmomanometer with a stethoscope. This method may be difficult for medical students that will use BP for medical evaluation. The purpose of this study was to compare the accuracy of double stethoscope devic...

متن کامل

Design and Implementation of an Automated Dispensing Device for Reducing Methadone Therapy Misuse

Introduction: A variety of (deliberate or inaccurate) errors in drug rehabilitation clinics may occur  due to use of addictive drugs. Automated drug distribution systems play a significant role in reducing drug medication errors. Method: Firstly, according to the addiction rehabilitation centers requests, the design and construction of the device was performed. The prototype systems were examin...

متن کامل

Comparison of Various Blood Pressure Measurement Techniques with Standard Office Based Blood Pressure Mesurement

Introduction: In order to control Hypertension, it is necessary to understand the methods of blood pressure measurement. Recent guidelines emphasize on employing appropriate blood pressure measurement techniques and white coat hypertension. Definition and methods of blood pressure measurement have changed in the American guideline based on SPRINT trial (Systolic Blood Pressure Intervention Tria...

متن کامل

Optimum frequency of office blood pressure measurement using an automated sphygmomanometer.

OBJECTIVE To determine the optimum interval between serial blood pressure measurements using an automated BpTRU sphygmomanometer. METHODS Two groups of 200 patients each had automated office measurements taken using the BpTRU device at either 1-min or 2-min intervals from the start of one reading to the start of the next reading with a 24-h ambulatory blood pressure (ABP) recording being perf...

متن کامل

Conventional versus automated measurement of blood pressure in primary care patients with systolic hypertension: randomised parallel design controlled trial

OBJECTIVE To compare the quality and accuracy of manual office blood pressure and automated office blood pressure using the awake ambulatory blood pressure as a gold standard. DESIGN Multi-site cluster randomised controlled trial. SETTING Primary care practices in five cities in eastern Canada. PARTICIPANTS 555 patients with systolic hypertension and no serious comorbidities under the car...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Archives of internal medicine

دوره 158 7  شماره 

صفحات  -

تاریخ انتشار 1998