Intensifier ( L 1 ) Field Lens a & G ( L 3 & L 4 ) Relay Lenses Ccd Screen Phosphorimage

نویسندگان

  • A. N. Ramaprakash
  • Ranjan Gupta
  • A. K. Sen
چکیده

| Taking advantage of the advances in array detector technology, an imaging polarimeter (IMPOL) has been constructed for measuring linear polarization in the wavelength band from 400-800 nm. It makes use of a Wollaston prism as the analyser to measure simultaneously the two orthogonal polarization components that deene a Stoke's parameter. An achromatic half-wave plate is used to rotate the plane of polarization with respect to the axis of the analyser so that the second Stoke's parameter also can be determined. With a eld of view correponding to about 30 30 mm 2 for a / 1.2 m, f/13 telescope, a sensitive, liquid-N2 cooled CCD camera as the detector and a built-in acquisition and guidance unit, the instrument can be used for studying stellar elds or extended objects with an angular resolution of 2 00. The instrumental polarization is less than 0.05% and the accuracies of measurement are primarily limited by photon noise for typical observations.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Analysis of the spatial-frequency-dependent DQE of optically coupled digital mammography detectors.

The effect of optical coupling efficiency on the spatial-frequency-dependent propagation of signal and noise is considered for x-ray image detectors for digital mammography in which a phosphor screen is optically coupled to a charge-coupled device (CCD) image array. For experimental purposes, optical coupling between a Gd2O2S:Tb phosphor screen and a CCD image array was provided by relay lenses...

متن کامل

Analysis of the power profile of a new soft contact lens for myopia progression

1. Wagner S, Conrad F, Bakaraju RC, Fedtke C, Ehrmann K, Holden BA. Power profiles of single vision and multifocal soft contact lenses. Cont Lens Anterior Eye. 2014;38:2--14. 2. Plainis S, Atchison DA, Charman WN. Power profiles of multifocal contact lenses and their interpretation. Optom Vis Sci. 2013;90:1066--1077. 3. Joannes L, Hough T, Hutsebaut X, et al. The reproducibility of a new power ...

متن کامل

Optical design and imaging performance testing of a 9.6-mm diameter femtosecond laser microsurgery probe.

We present the optical design of a 9.6-mm diameter fiber-coupled probe for combined femtosecond laser microsurgery and nonlinear optical imaging. Towards enabling clinical use, we successfully reduced the dimensions of our earlier 18-mm microsurgery probe by half, while improving optical performance. We use analytical and computational models to optimize the miniaturized lens system for off-axi...

متن کامل

UV filter compounds in human lenses: the origin of 4-(2-amino-3-hydroxyphenyl)-4-oxobutanoic acid O-beta-D-glucoside.

PURPOSE To investigate UV filter synthesis in the human lens, in particular the biosynthetic origin of the second most abundant UV filter compound, 4-(2-amino-3-hydroxyphenyl)-4-oxobutanoic acid O-beta-D-glucoside. METHODS Human lenses were analyzed by high-performance liquid chromatography (HPLC) after separate incubation with 3H-tryptophan (3H-Trp), beta-benzoylacrylic acid, D,L-alpha-amino...

متن کامل

The Palomar 200-inch f/9 Cassegrain CCD camera

This article describes the design and construction of a CCD camera for the f/9 Cassegrain focus of the 200-inch (5 m) Hale Telescope at Palomar Observatory. This instrument utilizes a set of 18inch (0.45 m) diameter lenses to change the Cassegrain focal ratio from f/16 to f/9, and the optical design prescription of these lenses is reported. For CCDs having 24zm pixels, the f/9 focus gives a rec...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008