Determination of heroin and its main metabolites in small sample volumes of whole blood and brain tissue by reversed-phase liquid chromatography-tandem mass spectrometry.

نویسندگان

  • Ritva Karinen
  • Jannike Mørch Andersen
  • Ase Ripel
  • Inger Hasvold
  • Anita Braute Hopen
  • Jørg Mørland
  • Asbjørg S Christophersen
چکیده

A high-performance liquid chromatography-tandem mass spectrometry (LC-MS-MS) method has been developed for the quantitative analysis of heroin and its major metabolites 6-acetylmorphine, morphine, morphine-3-glucuronide and morphine-6-glucuronide in blood and brain tissue, using 0.1-mL samples. We evaluated this method for analysis of heroin and its metabolites in samples from heroin treated mice. Ice-cold acidic buffer containing sodium fluoride was immediately added to blood and brain homogenate samples. Sample preparation was achieved by protein precipitation on ice-bath, using a mixture of ice-cold acetonitrile and methanol. The supernatant was evaporated to dryness, reconstituted with mobile phase, and injected into the chromatographic system. Separation was performed on a Xterra C18 column with gradient elution. The MS analysis was performed in positive ion mode, and multiple reaction monitoring (MRM) was used for drug quantification. The limits of quantification for the different opiates varied from 0.0007 to 0.02 mg/L in blood and from 0.002 to 0.06 microg/g in brain tissue. Day-to-day relative standard deviation ranged from 3.1 to 14.5%, and within-day variation ranged from 2.1 to 11.4%. The recoveries were between 80 and 111%. The stability of heroin was tested, and the study showed that heroin is more stable in brain tissue than in blood.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Relative Determination Approach to the Metabolites of Protoberberine Alkaloids in Rat Urine by Liquid Chromatography Tandem Mass Spectrometry for the Comparative Studies on Rhizome coptidis and Zuojinwan Preparation

The lack of authentic standards has limited the quantitative analysis of herbal drugs in biological samples. The present work demonstrated a practicable strategy for the assay of herbs and their metabolites independent of authentic standards. A liquid chromatography–electrospray ionization–mass spectrometry (LC–ESI–MS) method for the qualitative and quantitative determination of the metabolites...

متن کامل

Relative Determination Approach to the Metabolites of Protoberberine Alkaloids in Rat Urine by Liquid Chromatography Tandem Mass Spectrometry for the Comparative Studies on Rhizome coptidis and Zuojinwan Preparation

The lack of authentic standards has limited the quantitative analysis of herbal drugs in biological samples. The present work demonstrated a practicable strategy for the assay of herbs and their metabolites independent of authentic standards. A liquid chromatography–electrospray ionization–mass spectrometry (LC–ESI–MS) method for the qualitative and quantitative determination of the metabolites...

متن کامل

Liquid Chromatography Tandem Mass/Mass Spectrometry for the Quantification of Fudosteine in Human Serum without Precolumn Derivatization

A quantitative analysis method for fudosteine in human serum by high-performance liquid chromatography-electrospray ionization tandem mass spectrometry (HPLC-ESI/MS/MS) was established, which shows high sensitivity and selectivity. The mobile phase composition was 75% 20 mM acetic acid and 25% acetonitril, which was pumped at a flow rate of 0.40 mL/min. The overall chromatographic run time was ...

متن کامل

Liquid Chromatography Tandem Mass/Mass Spectrometry for the Quantification of Fudosteine in Human Serum without Precolumn Derivatization

A quantitative analysis method for fudosteine in human serum by high-performance liquid chromatography-electrospray ionization tandem mass spectrometry (HPLC-ESI/MS/MS) was established, which shows high sensitivity and selectivity. The mobile phase composition was 75% 20 mM acetic acid and 25% acetonitril, which was pumped at a flow rate of 0.40 mL/min. The overall chromatographic run time was ...

متن کامل

Determination of Mebudipine in Human Plasma by Liquid Chromatography–tandem Mass Spectrometry

In previous studies, mebudipine, a dihydropyridine calcium channel blocker, showed a considerable potential to be used in cardiovascular diseases. The aim of the current study was to develop a valid method using reversed-phase high performance liquid chromatography coupled with electrospray ionization mass spectrometry to assay mebudipine in the human plasma. Separation was achieved on a Zorbax...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of analytical toxicology

دوره 33 7  شماره 

صفحات  -

تاریخ انتشار 2009