Uncompromised quality of the cement mantle in Exeter femoral components implanted through a minimally-invasive direct anterior approach. A prospective, randomised cadaver study.

نویسندگان

  • E Mayr
  • M Krismer
  • M Ertl
  • O Kessler
  • M Thaler
  • M Nogler
چکیده

A complete cement mantle is important for the longevity of a total hip replacement. In the minimally-invasive direct anterior approach used at the Innsbruck University hospital, the femoral component has to be inserted into the femoral canal by an angulated movement. In a cadaver study, the quality and the extent of the cement mantle surrounding 13 Exeter femoral components implanted straight through a standard anterolateral transgluteal approach were compared with those of 13 similar femoral components implanted in an angulated fashion through a direct anterior approach. A third-generation cementing technique was used. The inner and outer contours of the cement mantles was traced from CT scans and the thickness and cross-sectional area determined. In no case was the cement mantle incomplete. The total mean thickness of the cement mantle was 3.62 mm (95% confidence interval 3.59 to 3.65). The mean thickness in the group using the minimally-invasive approach was 0.16 mm less than that in the anterolateral group. The distribution of the thickness was similar in the two groups. The mean thickness was less on the anteromedial and anterolateral aspect than on the posterior aspect of the femur. There is no evidence that the angulated introduction of Exeter femoral components in the direct anterior approach in cadavers compromises the quality, extent or thickness of the cement mantle.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effects of a less-invasive surgical technique on cement mantle quality in total knee arthroplasty.

The purpose of this study was to assess the effects of a less-invasive midvastus exposure during total knee arthroplasty (TKA) on cement mantle grade compared with a standard parapatellar arthrotomy and standard TKA. Fifty consecutive cemented minimally invasive TKAs using a midvastus approach, patellar subluxation without eversion, and less-invasive instrumentation were compared radiographical...

متن کامل

The posterior approach reduces the risk of thin cement mantles with a straight femoral stem design

BACKGROUND AND PURPOSE The properties of the cement mantle around a prosthesis are important. We investigated whether the surgical approach to the hip influences the quality and thickness of the cement mantle when using a straight femoral stem design. METHODS In a consecutive multi-surgeon series, we reviewed the radiographs of 270 patients after cemented Exeter total hip arthroplasty. 135 st...

متن کامل

Cement migration after THR. A comparison of charnley elite and exeter femoral stems using RSA.

Studies using roentgen stereophotogrammetric analysis (RSA) have shown that the femoral components of cemented total hip replacements (THR) migrate distally relative to the bone, but it is not clear whether this occurs at the cement-implant or the cement-bone interface or within the cement mantle. Our aim was to determine where this migration occurred, since this has important implications for ...

متن کامل

The Exeter Universal stem: a minimum ten-year review from an independent centre.

We reviewed 142 consecutive primary total hip replacements implanted into 123 patients between 1988 and 1993 using the Exeter Universal femoral stem. A total of 74 patients (88 hips) had survived for ten years or more and were reviewed at a mean of 12.7 years (10 to 17). There was no loss to follow-up. The rate of revision of the femoral component for aseptic loosening and osteolysis was 1.1% (...

متن کامل

A Minimum Ten-year Review from an Independent Centre

J Bone Joint Surg [Br] 2006;88-B:1584-90. Received 30 June 2006; Accepted after revision 15 August 2006 We reviewed 142 consecutive primary total hip replacements implanted into 123 patients between 1988 and 1993 using the Exeter Universal femoral stem. A total of 74 patients (88 hips) had survived for ten years or more and were reviewed at a mean of 12.7 years (10 to 17). There was no loss to ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of bone and joint surgery. British volume

دوره 88 9  شماره 

صفحات  -

تاریخ انتشار 2006