Exploring the impact of EGFR T790M neighboring SNPs on ARMS-based T790M mutation assay.
نویسندگان
چکیده
The present study aimed to explore the influence of T790M neighboring single nucleotide polymorphism (SNP) on the sensitivity of amplification refractory mutation system (ARMS)-based T790M mutation assay. Three ARMS-quantitative polymerase chain reaction (qPCR) systems (system 1 had a forward ARMS primer without rs1050171, system 2 included a forward ARMS primer with rs1050171 and system 3 contained the above two forward ARMS primers) were used to detect the T790M mutation in two series plasmid samples and genomic DNA (gDNA) of the cell line H1975. A total of 670 formalin-fixed paraffin-embedded (FFPE) tumor samples from non-small cell lung cancer patients were used to detect the epidermal growth factor receptor (EGFR) gene T790M mutation by direct sequencing and ARMS-qPCR. The ARMS-qPCR system 1 effectively detected samples with as low as 1% T790M mutant plasmid 1 (without rs1050171) and with 50% T790M mutant plasmid 2 (with rs1050171), while the ARMS-qPCR system 2 detected samples with 20 and 50% T790M mutant plasmid 1, in addition to samples with 1% T790M mutant plasmid 2. For the ARMS-qPCR system 3, samples with as low as 1% T790M mutant plasmids 1 or 2 were effectively detected. For gDNA analysis of the cell line H1975, the T790M mutation was effectively detected by the ARMS-qPCR systems 2 and 3 (~50% mutation rate), but was detected with a low mutation abundance by the ARMS-qPCR system 1 (~1% mutation rate). Of the 670 FFPE samples, 5 cases were identified to have the T790M mutation by sequencing and by the ARMS-qPCR system 1. One sample (named N067), which was considered as T790M-negative by sequencing, was demonstrated to have the T790M mutation using the ARMS-qPCR system 1. Sample N094, which was variant homozygous for rs1050171 and was indicated to be T790M-negative by sequencing and by the ARMS-qPCR system 1, was identified to have the T790M mutation with the ARMS-qPCR system 3. The A-variant allele frequency of rs1050171 was observed to be 28.2% in the 670 FFPE tumor samples, while the presence of rs148188503 (c. C2355T, p. T785T) was observed in sample N558, and a novel SNP with a base substitution (c. T2375C) at position 792 (p. L792P) in exon 20 of the EGFR gene was observed in sample N310. rs1050171 is a high-frequency SNP located near T790M, and the mutation statuses of rs1050171 appear to influence the sensitivity of the ARMS-based T790M detection system, thus generating a 14.3% false-negative rate (1/7). The present study proposes the risk that target neighboring SNPs (as far as 8 bp away in the present study) may exert on the sensitivity of ARMS-based detection methods.
منابع مشابه
A Comparison of ddPCR and ARMS for detecting EGFR T790M status in ctDNA from advanced NSCLC patients with acquired EGFR‐TKI resistance
A sensitive and convenient method for detecting epidermal growth factor receptor (EGFR) T790M mutations from circulating tumor DNA (ctDNA) in advanced non-small cell lung cancer (NSCLC) patients with acquired EGFR-TKI resistance would be desirable to direct patient sequential treatment strategy. A comparison of two platforms for detecting EGFR mutations in plasma ctDNA was undertaken. Plasma sa...
متن کاملQuantification and Dynamic Monitoring of EGFR T790M in Plasma Cell-Free DNA by Digital PCR for Prognosis of EGFR-TKI Treatment in Advanced NSCLC
BACKGROUND Among advanced non-small cell lung cancer (NSCLC) patients with an acquired resistance to epidermal growth factor receptor-tyrosine kinase inhibitors (EGFR-TKI), about 50% carry the T790M mutation, but this frequency in EGFR-TKI-naïve patients and dynamic change during therapy remains unclear. This study investigated the quantification and dynamic change of T790M mutation in plasma c...
متن کاملComparison of droplet digital PCR and conventional quantitative PCR for measuring EGFR gene mutation
Early detection of epidermal growth factor receptor (EGFR) mutation, particularly EGFR T790M mutation, is of clinical significance. The aim of the present study was to compare the performances of amplification refractory mutation system-based quantitative polymerase chain reaction (ARMS-qPCR) and droplet digital polymerase chain reaction (ddPCR) approaches in the detection of EGFR mutation and ...
متن کاملA comparison of QuantStudio™ 3D Digital PCR and ARMS-PCR for measuring plasma EGFR T790M mutations of NSCLC patients
Background The AURA3 clinical trial has shown that advanced non-small cell lung cancer (NSCLC) patients with EGFR T790M mutations in circulating tumor DNA (ctDNA) could benefit from osimertinib. Purpose The aim of this study was to assess the usefulness of QuantStudio™ 3D Digital PCR System platform for the detection of plasma EGFR T790M mutations in NSCLC patients, and compare the performanc...
متن کاملMeta-analysis of the impact of de novo and acquired EGFR T790M mutations on the prognosis of patients with non-small cell lung cancer receiving EGFR-TKIs
PURPOSE The purpose of this meta-analysis was to explore the influences of pretreatment de novo and posttreatment-acquired epidermal growth factor receptor (EGFR) T790M mutations in patients with advanced non-small cell lung cancer (NSCLC) who had received tyrosine kinase inhibitors (TKIs). METHODS We searched PubMed, Embase, and the China National Knowledge Infrastructure database for eligib...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Oncology letters
دوره 12 5 شماره
صفحات -
تاریخ انتشار 2016