Development of diamond-based X-ray detection for high-flux beamline diagnostics.
نویسندگان
چکیده
High-quality single-crystal and polycrystalline chemical-vapor-deposition diamond detectors with platinum contacts have been tested at the white-beam X28C beamline at the National Synchrotron Light Source under high-flux conditions. The voltage dependence of these devices has been measured under both DC and pulsed-bias conditions, establishing the presence or absence of photoconductive gain in each device. Linear response consistent with the theoretically determined ionization energy has been achieved over eleven orders of magnitude when combined with previous low-flux studies. Temporal measurements with single-crystal diamond detectors have resolved the nanosecond-scale pulse structures of both the NSLS and the APS. Prototype single-crystal quadrant detectors have provided the ability to simultaneously resolve the X-ray beam position and obtain a quantitative measurement of the flux.
منابع مشابه
X-ray beam monitor made by thin-film CVD single-crystal diamond.
A novel beam position monitor, operated at zero bias voltage, based on high-quality chemical-vapor-deposition single-crystal Schottky diamond for use under intense synchrotron X-ray beams was fabricated and tested. The total thickness of the diamond thin-film beam monitor is about 60 µm. The diamond beam monitor was inserted in the B16 beamline of the Diamond Light Source synchrotron in Harwell...
متن کاملHigh-resolution soft X-ray beamline ADRESS at the Swiss Light Source for resonant inelastic X-ray scattering and angle-resolved photoelectron spectroscopies
The concepts and technical realisation of the high-resolution soft X-ray beamline ADRESS operating in the energy range from 300 to 1600 eV and intended for resonant inelastic X-ray scattering (RIXS) and angle-resolved photoelectron spectroscopy (ARPES) are described. The photon source is an undulator of novel fixed-gap design where longitudinal movement of permanent magnetic arrays controls not...
متن کاملPhoton Diagnostics for the X-ray FELs at TESLA
An X-ray diagnostic station will be installed for each of the XFEL undulator beamlines at TESLA. Primary purpose of the X-ray diagnostics is to provide an additional tool for alignment and commissioning of the numerous undulator cells along an XFEL beamline independently from electron beam based alignment procedures. Both methods will complement one another. The X-ray diagnostic station will be...
متن کاملSynthetic diamond-based position-sensitive photoconductive detector development for the Advanced Photon Source.
A novel X-ray beam-position detection device that we call a position-sensitive photoconductive detector (PSPCD) is designed to have synthetic diamond as its substrate material. We proved that it is feasible to use synthetic diamond to make a hard X-ray position-sensitive detector based on the photoconductivity principle and that it acts as a solid-state ion chamber. Experiments on different PSP...
متن کاملEffect of Cyclotrimethylenetrinitramine on the WetSynthesis of Ultra-nanocrystalline Diamond
The Ultra-nanocrystalline diamond (UNCD) was synthesized by the detonation of a high explosive mixture in water confinement. The presence of a diamond phase was revealed by X-ray diffraction (XRD) and transmission electron microscopy (TEM). X-ray line broadening (XRLB) was used to evaluate the peak profiles of diamond nanoparticles and their corresponding average crystallite sizes. The micro st...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of synchrotron radiation
دوره 17 6 شماره
صفحات -
تاریخ انتشار 2010