Intramyocardial Blood Volume

نویسنده

  • Robert M. Judd
چکیده

We have measured the effects of barium-induced cardiac contraction on the intramyocardial blood volume content of all vessels and have independently measured the blood volume content of vessels with a diameter greater than 100 ,um in rat myocardium. Measurements of total intramyocardial blood volume were made by using [1251]albumin as a plasma marker and technetium-99m as a red blood cell marker. In one group of rats (n=8), diastolic arrest was induced by an intravenous injection of KCI; in a second group (n=8), systolic arrest was induced by an intravenous injection of BaCI2. In both groups, the hearts were frozen in situ immediately after heart arrest while aortic pressure was decaying from its former physiological level. The left ventricular free wall was sectioned transmurally in a cryomicrotome, and the blood volume within each tissue sample was calculated from its radioactivity. The volume of blood in vessels larger than 100 ,um was independently estimated from the exposed crosssectional area of these vessels in photographs of the frozen tissue taken during tissue sectioning in the cryomicrotome. Total intramyocardial blood volume was found to decrease by about 42% from 8.6+1.3 ml/100 g (mean±SEM) in the KCI group to 5.0±0.7 ml/100 g in the BaCI2 group (p<0.01). Total volume was greater in the epicardial than in the endocardial layers of both groups (p<0.05). The volume of blood contained in vessels larger than 100 ,um decreased from 1.2+0.3 ml/100 g in the KCI group to 0.3±0.1 ml/100 g in the BaCI2 group (p<0.05). The volume of blood contained in vessels smaller than 100 ,im, calculated by subtracting large-vessel volume from total volume, decreased from 7.4 ml/100 g in the KCI group to 4.6 ml/100 g in the BaCI2 group. These results show that barium-induced cardiac contraction strongly affects the volume of blood in the smaller coronary blood vessels. Although differences exist between barium contraction and a normal systolic contraction, the results suggest that during the normal cardiac cycle the small vessels play an important role in the determination of phasic coronary blood flow. (Circulation Research 1991;68:217-225)

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of coronary stenosis on adjacent bed flow reserve: assessment of microvascular mechanisms using myocardial contrast echocardiography.

BACKGROUND During coronary stenosis, flow reserve in the adjacent nonstenotic bed decreases, but the microvascular mechanisms are unknown. Because myocardial contrast echocardiography (MCE) assesses microvascular physiology, we used it to relate flow reserve to intramyocardial blood volume in the adjacent bed. METHODS AND RESULTS A noncritical left anterior descending (LAD) stenosis was creat...

متن کامل

Coronary diastolic pressure-flow relation and zero flow pressure explained on the basis of intramyocardial compliance.

In the controversy about the mechanisms determining the high zero flow pressures and the further interpretation of coronary diastolic pressure flow relations, this paper takes a stand in favor of intramyocardial compliance as the primary cause of the high zero flow pressures. An attempt has been made to estimate the compliance distribution within the coronary circulation and to show the specifi...

متن کامل

Cardiac micro-computed tomography imaging of the aging coronary vasculature.

BACKGROUND Alterations at the level of the coronary circulation with aging may play an important role in the evolution of age-associated changes in left ventricular (LV) fibrosis and function. However these age-associated changes in the coronary vasculature remain poorly defined primarily due to the lack of high resolution imaging technologies. The current study was designed to utilize cardiac ...

متن کامل

First-pass entry of nonionic contrast agent into the myocardial extravascular space. Effects on radiographic estimates of transit time and blood volume.

BACKGROUND Almost all x-ray-based techniques intended to assess regional myocardial perfusion from myocardial concentration-time curves following the administration of soluble contrast agents assume that these agents behave as intravascular indicators and can therefore provide measurements of intravascular transit time and intramyocardial blood volume. METHODS AND RESULTS We tested this assum...

متن کامل

Diastolic-systolic coronary flow differences are caused by intramyocardial pump action in the anesthetized dog.

The effect of cardiac contraction on coronary arterial flow has been described in terms of an intramyocardiaJ pump, which displaces blood backward and forward during systole and diastole, respectively. Normally, the mean forward flow exceeds, and consequently conceals, this backflow. The main left coronary artery of six anesthetized open-chest dogs was perfused with a Gregg cannula from a const...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2005