Imageless computer navigation for placement of the femoral component in resurfacing arthroplasty of the hip.

نویسندگان

  • M Olsen
  • E T Davis
  • J P Waddell
  • E H Schemitsch
چکیده

We have investigated the accuracy of placement of the femoral component using imageless navigation in 100 consecutive Birmingham Hip Resurfacings. Pre-operative templating determined the native neck-shaft angle and planned stem-shaft angle of the implant. The latter were verified post-operatively using digital anteroposterior unilateral radiographs of the hip. The mean neck-shaft angle determined before operation was 132.7 degrees (118 degrees to 160 degrees ). The mean planned stem-shaft angle was a relative valgus alignment of 9.7 degrees (SD 2.6). The stem-shaft angle after operation differed from that planned by a mean of 2.8 degrees (SD 2.0) and in 86% of cases the final angle measured within +/- 5 degrees of that planned. We had no instances of notching of the neck or varus alignment of the implant in our series. A learning curve was observed in the time taken for navigation, but not for accurate placement of the implant. Navigation in hip resurfacing may afford the surgeon a reliable and accurate method of placement of the femoral component.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A simple and reliable technique for placing the femoral neck guide pin in hip resurfacing arthroplasty.

Early failure of hip resurfacing has been attributed to component malposition and other factors. Accurate placement of the femoral guide pin is challenging with commercial guides, and computer navigation adds considerable cost to the procedure. Precise pin placement can be achieved by drilling a 2.8-mm pin across the hip joint in a retrograde fashion similar to placing a dynamic hip screw pin. ...

متن کامل

Imageless computer navigation without pre-operative templating may lead to malpreparation of the femoral head in hip resurfacing.

The computed neck-shaft angle and the size of the femoral component were recorded in 100 consecutive hip resurfacings using imageless computer-navigation and compared with the angle measured before operation and with actual component implanted. The reliability of the registration was further analysed using ten cadaver femora. The mean absolute difference between the measured and navigated neck-...

متن کامل

Validation of the femoral anteversion measurement method used in imageless navigation

Total hip arthroplasty restores lost mobility to patients suffering from osteoarthritis and acute trauma. In recent years, navigated surgery has been used to control prosthetic component placement. Furthermore, there has been increasing research on what constitutes correct placement. This has resulted in the definition of a safe-zone for acetabular cup orientation. However, there is less defini...

متن کامل

The use of computer navigation in hip arthroplasty: literature review and evidence today.

Total hip replacement arthroplasty and hip resurfacing are two of the most successful orthopaedic operations performed worldwide. Critical to the success of these operations is the accurate placement of the components. Correct component alignment reduces mechanical wear and the risk of dislocation. Traditionally, correct component alignment relies on the surgeon referencing from the position of...

متن کامل

Imageless navigation for insertion of the acetabular component in total hip arthroplasty: is it as accurate as CT-based navigation?

In a prospective randomised clinical study acetabular components were implanted either freehand (n = 30) or using CT-based (n = 30) or imageless navigation (n = 30). The position of the component was determined post-operatively on CT scans of the pelvis. Following conventional freehand placement of the acetabular component, only 14 of the 30 were within the safe zone as defined by Lewinnek et a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of bone and joint surgery. British volume

دوره 91 3  شماره 

صفحات  -

تاریخ انتشار 2009