IMAGING Technical Aspects of Sentinel Node Lymphoscintigraphy for Breast Cancer

نویسندگان

  • Lisa K. Dunnwald
  • David A. Mankoff
  • David R. Byrd
  • Benjamin O. Anderson
  • Roger E. Moe
  • Raymond S. Yeung
  • Janet F. Eary
چکیده

Objective: A significant morbidity risk is associated with axillary nodal dissections for breast cancer. Many treatment decisions are based on axillary nodal status. Lymphatic mapping and sentinel node biopsy have been investigated to determine if the histology of the sentinel node reflects the remaining lymph node basin. We describe the technical aspects of sentinel node lymphoscintigraphy for breast cancer. Methods: Ninety-three patients had lymphoscintigraphy for breast cancer. Patients with palpable lesions had 4 concentric injections around the site and lesions requiring localization had injections made through tubing connected to the localizing wire introducer needle. Immediate static images were acquired and the sentinel node was marked for surgery. Marks were reverified using a handheld gamma probe. Results: Lymph nodes were visualized by lymphoscintigraphy in 87% of cases. Time to visualization of lymph nodes ranged from 1–120 min with a mean of 28 min. An average of 1.5 nodes were visualized. The overall success rate for identifying the sentinel node at time of surgery was 85%. Conclusion: We conclude that lymphoscintigraphy for breast cancer is a detailed procedure that requires coordination with radiology and surgery teams to ensure proper identification of sentinel lymph nodes.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Time frame of sentinel node visualization in early breast cancer patients using intradermal injection of Tc-99m phytate: Imaging beyond 45 minutes does not yield more information

Introduction: One of the major problems of lymphoscintigraphy is the time of patient presence in the nuclear medicine wards. The operating room schedule can be compromised if the patients stay longer than usual in the nuclear medicine departments. However, too early imaging can be falsely negative for sentinel node visualization and delayed imaging may be required. The aim of t...

متن کامل

Dynamic lymphoscintigraphy in breast cancer patients: feasibility and added value

Introduction: Lymphoscintigraphy is imaging of the lymphatic system and has been integrated into the sentinel node mapping procedures. Lymphoscintigraphy usually encompasses early or delayed static images. However, immediate dynamic imaging of the lymphatic basins and tumors has also been used as an adjunct lymphoscintigraphy imaging. The aim of this study was ...

متن کامل

Sentinel node mapping for early breast cancer patients using 99mTc-phytate: Single center experience on 165 patients

Introduction: Several radiotracers are being used for sentinel node mapping in patients with breast cancer. In the current study, we reported our experience with 99m-Tc Phytate for sentinel node mapping in Mashhad University of Medical Sciences. Methods: All breast cancer patients who underwent sentinel node mapping using 99m-Tc Phytate were included. All patients received intradermal peri-are...

متن کامل

Radiotracer re-injection in case of sentinel node non-visualization in a breast cancer patient

We reported a 35 year old breast cancer patient who was referred to our nuclear medicine department for sentinel node mapping. She was planned to undergo mastectomy and lymphatic mapping. A dose of Tc-99m Phytate was injection in the peri-areolar region in an intra-dermal fashion. Two hours post-injection no sentinel node was visible in the axilla. Due to a high liver uptake, inadvertent intra-...

متن کامل

Inappropriate cervical injection of radiotracer for sentinel node mapping in a uterine cervix cancer patient: importance of lymphoscintigraphy and blue dye injection

Herein, we report a case of sentinel lymph node mapping in a uterine cervix cancer patient, referring to the nuclear medicine department of our institute. Lymphoscintigraphy images showed inappropriate intra‐cervical injection of radiotracer. Blue dye technique was applied for sentinel lymph node mapping, using intra‐cervical injection of methylene blue. Two blue/cold sentinel lymph nodes, with...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2001