Effect of chlorhexidine/silver sulfadiazine-impregnated central venous catheters in an intensive care unit with a low blood stream infection rate after implementation of an educational program: a before-after trial.
نویسندگان
چکیده
BACKGROUND Current guidelines recommend using antiseptic- or antibiotic-impregnated central venous catheters (CVCs) if, following a comprehensive strategy to prevent catheter-related blood stream infection (CR-BSI), infection rates remain above institutional goals based on benchmark values. The purpose of this study was to determine if chlorhexidine/silver sulfadiazine-impregnated CVCs could decrease the CR-BSI rate in an intensive care unit (ICU) with a low baseline infection rate. METHODS Pre-intervention and post-intervention observational study in a 24-bed surgical/trauma/burn ICU from October, 2002 to August, 2005. All patients requiring CVC placement after March, 2004 had a chlorhexidine/silver sulfadiazine-impregnated catheter inserted (post-intervention period). RESULTS Twenty-three CR-BSIs occurred in 6,960 catheter days (3.3 per 1,000 catheter days)during the 17-month control period. After introduction of chlorhexidine/silver sulfadiazine-impregnated catheters, 16 CR-BSIs occurred in 7,732 catheter days (2.1 per 1,000 catheter days; p = 0.16). The average length of time required for an infection to become established after catheterization was similar in the two groups (8.4 vs. 8.6 days; p = 0.85). Chlorhexidine/silver sulfadiazine-impregnated catheters did not result in a statistically significant change in the microbiological profile of CR-BSIs, nor did they increase the incidence of resistant organisms. CONCLUSIONS Although chlorhexidine/silver sulfadiazine-impregnated catheters are useful in specific patient populations, they did not result in a statistically significant decrease in the CR-BSI rate in this study, beyond what was achieved with education alone.
منابع مشابه
Cost-effectiveness of antiseptic-impregnated central venous catheters for the prevention of catheter-related bloodstream infection.
CONTEXT A recent randomized controlled trial and meta-analysis indicated that central venous catheters impregnated with an antiseptic combination of chlorhexidine and silver sulfadiazine are efficacious in reducing the incidence of catheter-related bloodstream infection (CR-BSI); however, the ultimate clinical and economic consequences of their use have not been formally evaluated. OBJECTIVE ...
متن کاملEffect of a second-generation venous catheter impregnated with chlorhexidine and silver sulfadiazine on central catheter-related infections: a randomized, controlled trial.
BACKGROUND Central venous catheter-related infections are a significant medical problem. Improved preventive measures are needed. OBJECTIVE To ascertain 1) effectiveness of a second-generation antiseptic-coated catheter in the prevention of microbial colonization and infection; 2) safety and tolerability of this device; 3) microbiology of infected catheters; and 4) propensity for the developm...
متن کاملIncidence of Central Venous Catheter-Related Infection and Risk Factors in Critically Ill Post-Operative Cancer Patients: A Randomized Prospective Cohort Study
Background: Cancer patients are susceptive to infection. Catheter-related bloodstream infections are the first cause of nosocomial bloodstream infections in intensive care units. Objectives: The aim of this study was to evaluate the association between the type of central intravenous catheter and bloodstream infection in post-operative cancer surgery patients at surgery intensive care units (IC...
متن کاملPrevention of central venous catheter-related bloodstream infection by use of an antiseptic-impregnated catheter. A randomized, controlled trial.
BACKGROUND Bloodstream infection related to short-term use of noncuffed central venous catheters is a common and serious problem. Technologic innovations to reduce the risk for these infections are needed. OBJECTIVE To determine 1) the efficacy of a novel antiseptic catheter in preventing central venous catheter-related infection, 2) patient tolerance of this catheter, and 3) the sources of b...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Surgical infections
دوره 8 4 شماره
صفحات -
تاریخ انتشار 2007