Specimen materials, target values and commutability for external quality assessment (proficiency testing) schemes.

نویسنده

  • W Greg Miller
چکیده

BACKGROUND The objective of external quality assessment is to evaluate clinical acceptability of laboratory results. It is desirable to evaluate intermethod harmonization and traceability to a reference system. METHODS Conventional matrix-modified processed materials are used in most programs, because they can be produced in large quantities, can have multiple abnormal analytes in the same vial and have excellent stability. The principal limitation of these materials is non-commutability which makes them unsuitable for traceability or harmonization evaluation. Peer group evaluation is used which allows an individual laboratory to confirm appropriate use of a measurement technology and a manufacturer to monitor uniformity in their calibration transfer process. Authentic clinical specimen pools provide commutability but are limited by the quantity available and number of analytes at pathologic levels in the same vial. Hybrid approaches have used authentic clinical specimen pools in conjunction with non-commutable processed materials to determine method-specific matrix-corrected target values which have enabled evaluation of traceability to reference methods. CONCLUSIONS Conventional processed materials are limited by non-commutability. Pooled clinical specimens are limited by availability. When used together, external quality assessment can evaluate traceability to reference systems and harmonization between test procedures.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Behavior of frozen serum pools and lyophilized sera in an external quality-assessment scheme.

To further improve analytical accuracy in clinical chemistry, proficiency testing needs amelioration in the quality of materials tested and in target value assignment. To obtain information on the actual state-of-the-art in the Lombardy region of Italy, and to examine the behavior of different types of control materials (fresh-frozen human sera and lyophilized materials), we developed the follo...

متن کامل

Commutability still matters.

Commutability is a property of a reference material such that values measured for that reference material and for representative clinical samples have the same relationship between 2, or more, measurement procedures for the same measurand (1, 2 ). Commutability is required when a reference material will be used as a common calibrator for clinical laboratory measurement procedures or will be use...

متن کامل

Implementing a regional integrated laboratory proficiency testing scheme for peripheral health facilities in East Africa

INTRODUCTION Regular participation in external quality assessment (EQA) is critical for maintaining laboratory performance and is required for laboratory accreditation. Proficiency testing (PT) is effective for providing EQA, but available schemes rarely address the range of tests performed by peripheral laboratories in resource-limited settings. The East African Regional External Quality Asses...

متن کامل

Assessing analytical accuracy through proficiency testing: have effects of matrix been overstated?

We read with great interest the report of Stepman et al. (1 ) identifying analytical errors in commercial analytical systems by using an external quality assessment (EQA) scheme with single-donor specimens. The use of such materials provides an assessment of method accuracy that is generally regarded as the gold standard in such comparisons (2 ). Unfortunately, only a limited number of laborato...

متن کامل

Proficiency testing/external quality assessment: current challenges and future directions.

BACKGROUND Proficiency testing (PT), or external quality assessment (EQA), is intended to verify on a recurring basis that laboratory results conform to expectations for the quality required for patient care. CONTENT Key factors for interpreting PT/EQA results are knowledge of the commutability of the samples used and the process used for target value assignment. A commutable PT/EQA sample de...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinica chimica acta; international journal of clinical chemistry

دوره 327 1-2  شماره 

صفحات  -