EPRI’s SF6 Management Program

نویسنده

  • Ben Damsky
چکیده

Introduction Sulfur hexafluoride (SF 6) gas is widely used in circuit breakers and gas-insulated substations, but its use presents safety and environmental challenges when maintenance is needed. Utilities using SF 6 gas have a variety of needs, including best practices for handling SF 6 , new tools for detecting and mitigating leaks, and information on assessing gas purity. In recent years, EPRI has conducted research and developed tools to meet these needs. The tools will assist utilities in adopting handling procedures that are safe, economical, and environmentally sound; detecting leaks cost-effectively and reducing the cost of replacement gas; and evaluating gas quality. Background SF 6 gas has a number of qualities that make it useful as a dielectric medium for electric utility applications. It has a high dielectric strength, is not corrosive to metals at ambient temperatures, and is chemically and thermally stable, nontoxic, and nonflammable.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The SF6 ReUse Program – A Case Study

Solvay has launched its SF6 ReUse Program in the USA, offering utility companies in particular the opportunity to dispose of their used SF6 gas in a manner consistent with environmental awareness and protection. The program addresses the analysis, transport and reclaiming of used SF6 gas to the point where it is ultimately fed back into the production stream. This paper illustrates the logistic...

متن کامل

CDM in Sub-Stations by Replacement of SF6 Gas in Circuit Breaker

This paper gives a case of large Sub-Station Clean Development Mechanism (CDM) Project to analyze CDM project’s influence on India’s Sustainable Development. SF6 gas is being extensively used in circuit breakers. SF6 gas has the highest Global warming potential which is 23900 times of Carbon Dioxide. Extensive Survey of SubStation using SF6 circuit breaker has been done in a sample state of Ind...

متن کامل

Learning Lessons Intelligently in the Electric Power Industry

Exponent Failure Analysis Associates 149 Commonwealth Drive Menlo Park, CA 94025 [email protected] EPRI (formerly the Electric Power Research Institute), behalf of its member companies worldwide, has initiated a strategic research program in Human Performance (HP), designed to enhance HP management by development of approaches and tools for anticipating, monitoring, and addressing factors wit...

متن کامل

Atmospheric SF<sub>6</sub> Near a Large Urban Area

Sulfur hexafluoride (SF6) has the potential to be a valuable transient racer for dating of young ground water. However, near urban areas, there are typically numerous point sources of SF6 which have a significant impact on the temporal evolution of its atmospheric mixing ratio, thereby complicating its use as an age-dating tool. Here, we present and discuss a 12-month record of atmospheric SF6 ...

متن کامل

[Management of Descemet's membrane rupture by intracameral injection of SF6 in acute hydrops].

CASE REPORT Hydrops occurring in the eye secondary to keratoconus, grade 4. It was managed by sulfur hexafluoride (SF6) gas injected into the anterior chamber, with an early resolution of corneal edema obtained. DISCUSSION Intervention with intracameral SF6 injection has proven to be a safe and effective therapy for early reduction of corneal edema in an eye with Descemet's membrane detachmen...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2000