Troubleshooting for Ureteroscopy Complicated by Unexpected Guidewire Looping and Entrapment

نویسندگان

  • Ioannis Efthimiou
  • Zacharias Chousianitis
  • Kostadinos Skrepetis
چکیده

This report presents a bizarre and unusual case of looping and entrapment of a hydrophilic guidewire in the ureter of a 65-year-old woman with a stone in the lower ureter at the time of ureteroscopy and laser lithotripsy. We describe endourology maneuvers to remove the retained guidewire. Looping and entrapment of guidewire is a rare complication that urologists may face when they do not follow the basic principles of guidewire insertion. In that case, successful resolution is based both on surgeon's inspiration to apply the appropriate endourology maneuvers and availability of a variety of endourology tools in the theater. Both may lead urologists to avoid more invasive and morbid approaches for their patients.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A complication of subclavian venous catheterization: extravascular kinking, knotting, and entrapment of the guidewire -A case report-

Various complications of central venous catheterization have been reported, some of which are well-known, while others are described as a sporadic events. We experienced a case of left subclavian venous catheterization complicated by extravascular knotting, kinking, and entrapment of the guidewire and the guidewire was removed surgically. Although minimal resistance was encountered during guide...

متن کامل

Zebra guidewire damage by Holmium: YAG laser and management of removal.

The zebra guidewire is widely used in endoscopic surgery. Because of its central mental core, it is not easy to break or shear off within the urinary tract. We report a case about the breakage of zebra guidewire in ureteroscopy (URS) with Holmium: YAG laser lithotripsy. It is easily to be managed by percutaneous access or open surgery. For the purpose of minimal invasiveness and risk, we perfor...

متن کامل

Is a safety guidewire needed for retrograde ureteroscopy?

INTRODUCTION It is generally advised to have a safety guidewire (SGW) present during ureteroscopy (URS) to manage possible complications. However, it increases the strenght needed to insert and retract the endoscope during the procedure, and, currently, there is a lack of solid data supporting the need for SGW in all procedures. We reviewed the literature about SGW utilization during URS. MET...

متن کامل

Comprehensive flexible ureteroscopy (FURS) simulator for training in endourology: The K-box model.

Over the last two decades there has been an increase in the incidence of kidney stone disease with a simultaneous rise in the use of ureteroscopy for its management [1]. Flexible ureteroscopy training is variable and still largely dependent on high fidelity models and virtual reality (VR) simulation, both of which are expensive and not readily available in many parts of the world. There is also...

متن کامل

Tips and tricks of ureteroscopy: consensus statement Part I. Basic ureteroscopy

Ureteroscopy is fast becoming the first line treatment option for the majority of urinary tract stones. Ureteroscopy training can be performed in a variety of ways including simulation, hands on ureteroscopy courses and supervised operative experience. We report an "expert consensus view" from experienced endourological surgeons, on all aspects of basic ureteroscopic techniques, with a particul...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 3  شماره 

صفحات  -

تاریخ انتشار 2017