Monitoring Changes in Hepatic Venous Velocities Flow after a Fluid Challenge Can Identify Shock Patients Who Lack Fluid Responsiveness
نویسندگان
چکیده
BACKGROUND Evaluating the hemodynamic status and predicting fluid responsiveness are important in critical ultrasound assessment of shock patients. Transthoracic echocardiography with noninvasive diagnostic parameters allows the assessment of volume responsiveness. This study aimed to assess the hemodynamic changes in the liver and systemic hemodynamic changes during fluid challenge and during passive leg raising (PLR) by measuring hepatic venous flow (HVF) velocity. METHODS This is an open-label study in a tertiary teaching hospital. Shock patients with hypoperfusion who required fluid challenge were selected for the study. Patients <18 years old and those with contraindications to PLR were excluded from the study. Baseline values were measured, PLR tests were performed, and 500 ml of saline was infused over 30 min. Parameters associated with cardiac output (CO) in the left ventricular outflow tract were measured using the Doppler method. In addition, HVF velocity and right ventricular function parameters were determined. RESULTS Middle hepatic venous (MHV) S-wave velocity was positively correlated in all patients with CO at baseline (r = 0.706, P< 0.01) and after volume expansion (r = 0.524, P= 0.003). CO was also significantly correlated with MHV S-wave velocity in responders (r = 0.608, P< 0.01). During PLR, however, hepatic venous S-wave velocity did not correlate with CO. For the parameter ΔMHV D (increase in change in MHV D-wave velocity after volume expansion), defined as (MHV DafterVE - MHV DBaseline)/MHV DBaseline× 100%, >21% indicated no fluid responsiveness, with a sensitivity of 100%, a specificity of 71.2%, and an area under the receiver operating characteristic curve of 0.918. CONCLUSIONS During fluid expansion, hepatic venous S-wave velocity can be used to monitor CO, whether or not it is increasing. ΔMHV D ≥21% indicated a lack of fluid responsiveness, thus helping to decide when to stop infusions.
منابع مشابه
SvO2 to monitor resuscitation of septic patients: let's just understand the basic physiology
Real-time monitoring of mixed venous oxygen blood saturation (SvO2) or of central venous oxygen blood saturation is often used during resuscitation of septic shock. However, the meaning of these parameters is far from straightforward. In the present commentary, we emphasize that SvO2--a global marker of tissue oxygen balance--can never be simplistically used as a marker of preload responsivenes...
متن کاملPulse pressure variation and prediction of fluid responsiveness in patients ventilated with low tidal volumes
OBJECTIVE To determine the utility of pulse pressure variation (ΔRESP PP) in predicting fluid responsiveness in patients ventilated with low tidal volumes (V T) and to investigate whether a lower ΔRESP PP cut-off value should be used when patients are ventilated with low tidal volumes. METHOD This cross-sectional observational study included 37 critically ill patients with acute circulatory f...
متن کاملShould microcirculation monitoring be used to guide fluid resuscitation in severe sepsis and septic shock?
Tissue hypoperfusion and subsequent limited oxygen transport are critical features conducting to organ failure during shock states. Therefore, early identification of tissue hypoperfusion and adequate resuscitation are key for improving the probability of survival after septic shock.(1,2) However, how to identify organ perfusion abnormalities at the bedside and select the type and amount of flu...
متن کاملAn increase in aortic blood flow after an infusion of 100 ml colloid over 1 minute can predict fluid responsiveness: the mini-fluid challenge study.
BACKGROUND Predicting fluid responsiveness remains a difficult question in hemodynamically unstable patients. The author's objective was to test whether noninvasive assessment by transthoracic echocardiography of subaortic velocity time index (VTI) variation after a low volume of fluid infusion (100 ml hydroxyethyl starch) can predict fluid responsiveness. METHODS Thirty-nine critically ill v...
متن کاملPerioperative fluid management in kidney transplantation: a black box
The incidence of delayed graft function in patients undergoing kidney transplantation remains significant. Optimal fluid therapy has been shown to decrease delayed graft function after renal transplantation. Traditionally, the perioperative volume infusion regimen in this patient population has been guided by central venous pressure as an estimation of the patient's volume status and mean arter...
متن کامل