An overview of cochlear implant electrode array designs

نویسندگان

  • Anandhan Dhanasingh
  • Claude Jolly
چکیده

Cochlear implant electrode arrays are designed with specific characteristics that allow for the preservation of intra-cochlear structures during the insertion process, as well as during explantation. Straight lateral wall (LW) electrode arrays and pre-curved modiolar hugging (MH) electrode arrays are the two types that are commercially available. Although there is a third type of electrode array called the mid-scala (MS), which is positioned in the middle of the scala tympani (ST), and is usually considered as an MH type of electrode. Different lengths of straight LW electrode arrays are currently available which allow for insertion across a range of different sized cochleae; however, due to manufacturing limitations, pre-curved MH electrodes are generally only available to cover the basal turn of the cochlea, while the spiral ganglion cells are distributed in the Rosenthal's canal that extends into 1.75 turns of the cochlea. Both straight LW and pre-curved MH electrodes can cause a certain degree of intra-cochlear trauma, but pre-curved MH electrodes tend to deviate into the scala vestibuli from the scala tympani more often than the straight LW electrodes, resulting in damage to the osseous spiral lamina/spiral ligament which could initiate new bone formation and eventually affect the cochlear implant users' hearing performance. Structural damage to the cochlea could also affect the vestibular function. With pre-curved MH electrodes, higher degrees of trauma are related to the fixed curling geometry of the electrode in relation to the variable coiling pattern of individual cochleae, the orientation of the electrode contacts in relation to the modiolus wall, and how effectively the stylet was handled by the surgeon during the procedure. Wire management, metal density, and the shore hardness of the silicone elastomer all contribute to the stiffness/flexibility of the electrode. It is important to acknowledge the impact of bringing the stimulating contacts closer to the modiolus wall with an MH electrode type in terms of the resultant damage to intra-cochlear structures. The presence of malformed cochleae should be identified and appropriate electrodes should be chosen for each specific cochlea, irrespective of the cochlear implant brand. In order to utilize drug therapy, the cochlea should be free from any trauma.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Investigating the Effect of Cochlear Size in Insertion of Electrode Depth in Patients with Cochlear Implantation evaluated by CT-Scan

Background Cochlear implant surgery is an invasive procedure for patients with bilateral Sensorineural hearing loss and may cause some risks such as cochlear damage. We aimed to evaluate the effectiveness of cochlear measures obtained by computed tomography (CT) scan in predicting depth of cochlear implant insertion. Materials and Methods This study was conducted in a retrospective and cross-se...

متن کامل

Pneumococcal meningitis post-cochlear implantation: preventative measures.

OBJECTIVE Both clinical data and laboratory studies demonstrated the risk of pneumococcal meningitis post-cochlear implantation. This review examines strategies to prevent post-implant meningitis. DATA SOURCES Medline/PubMed database; English articles after 1980. Search terms: cochlear implants, pneumococcus meningitis, streptococcus pneumonia, immunization, prevention. REVIEW METHODS Narra...

متن کامل

Comparison of electrode position in the human cochlea using various perimodiolar electrode arrays.

OBJECTIVE This study was conducted to evaluate the insertion properties and intracochlear trajectories of three perimodiolar electrode array designs and to compare these designs with the standard Cochlear/Melbourne array. BACKGROUND Advantages to be expected of a perimodiolar electrode array include both a reduction in stimulus thresholds and an increase in dynamic range, resulting in a more ...

متن کامل

SURGICAL ASPECTS OF PEDIATRIC COCHLEAR IMPL A NTATION

Since 1991,90 cochlear implantations have been performed in the " cochlear center" of our department, including 57 children. This paper presents the results of 57 children who underwent cochlear implantation in the Iranian pediatric cochlear implant program. The surgical technique is described below. No flap problems were encountered, and no cholesteatoma or other complication was seen. In...

متن کامل

Interactions between cochlear implant electrode insertion depth and frequency-place mapping.

While new electrode designs allow deeper insertion and wider coverage in the cochlea, there is still considerable variation in the insertion depth of the electrode array among cochlear implant users. The present study measures speech recognition as a function of insertion depth, varying from a deep insertion of 10 electrodes at 28.8 mm to a shallow insertion of a single electrode at 7.2 mm, in ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Hearing Research

دوره 356  شماره 

صفحات  -

تاریخ انتشار 2017