Use of lead shields for radiation protection of superficial organs in patients undergoing head CT examinations.
نویسندگان
چکیده
Head computed tomography examinations are often accompanied with unnecessary irradiation of superficial organs that are rarely the main target for the investigation. The aim of this work is to demonstrate that lead shields could be effectively used to protect superficial organs without compromising image quality where superficial organ itself is not a target and that the irradiation of the superficial organ is unavoidable. The objective was achieved by first assessing the image quality using phantom measurements made with and without lead shielding in order to determine optimal shielding thickness for patient applications. The entrance surface doses (ESDs) to superficial organs of sixty patients were measured using LiF-thermoluminescent dosemeters without, with one layer, or with two layers of lead shields. Phantom studies demonstrated that the use of modified lead shields of up to 0.25 mm thickness could be used without significant effect on the image quality for central and posterior regions. In these studies, lead shields of 0.25 mm thickness reduce the ESDs to the lens of the eyes and thyroid by 44 and 51%, respectively. The image quality reduction by eye shields was significant to the anterior (i.e. orbital) region but marginal to the central and posterior regions (cerebrum). In view of the above, the use of modified lead shields could reduce the dose to the superficial organs considerably without significantly compromising image quality.
منابع مشابه
Review and Performance Comparison of Lead-Free Shields and Lead Shields, In Terms of Biological Effects in Nuclear Medicine by the Comet Method
Introduction: Ionizing radiation can cause damage to biologically important DNA molecules. Radiation in nuclear medicine radiation exposes people working in from two main positions; administer in gradiopharmaceuticals (the barn and squeezing a generator, procurement, distribution and drug infusion) and patients that receive radiation treatment (patients that are prescribed a ra...
متن کاملDiagnostic Reference Levels for Computed Tomography Examinations in Iran: A Nationwide Radiation Dose Survey
Introduction: International Commission on Radiological Protection introduced three basic principles of radiation protection, namely justification, optimization, and dose limit. Medical exposure has no dose limits, and generally, diagnostic reference levels are used as a tool for optimization of patient protection. Material and Methods: Dosimetry was performed on 20 CT scanners located in 14 cit...
متن کاملEvaluation of X-ray protective shielding used in dental offices in Kerman, Iran, in 2014
BACKGROUND AND AIM: Protective equipment, such as lead aprons and thyroid shields, is effective in reducing patient radiation. This study was conducted for evaluation the use of thyroid shields and lead aprons in dental offices, in Kerman, Iran, in June 2014.METHODS: In this descriptive-analytical study, 106 dental offices with active X-ray machines were evaluated in Kerman. The information was...
متن کاملEstimation of Absorbed and Effective Doses in Organs through Computed Tomography Examinations Using Automatic Exposure Control and Fixed Tube Current Techniques: A Phantom Case Study
Introduction: The study aimed to assess absorbed and effective doses in organs through computed tomography (CT) examinations using automatic exposure control (AEC) and fixed tube current (FTC) techniques. Material and Methods: Scanning parameters were obtained for routine adult CT examinations and used to estimate the organ absorbed and effec...
متن کاملApplication of Different methods for Reducing Radiation Dose to Breast during MDCT
The increased use of computed tomography (CT) and its high radiation dose have led to great concerns about its potential for radiation induced cancer risks. Breast is a radiosensitive tissue based on tissue weighting factors assigned by the International Commission on Radiological Protection (ICRP). Moreover, the dose is maximal on the surface of the patient. Therefore, strategies should be tak...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Radiation protection dosimetry
دوره 130 4 شماره
صفحات -
تاریخ انتشار 2008