Persistence of indentation with bioabsorbable poly-L/D-lactide versus silicone sponge scleral buckling implants.
نویسندگان
چکیده
PURPOSE To measure the amount and duration of indentation depth achieved with biodegradable poly-L/D-lactide 96/4 (PLA96) and silicone sponge implants. METHODS Thirty rabbits underwent a scleral buckling procedure. A PLA96 buckling implant was used in 15 rabbits and a silicone sponge buckling implant was in 15 rabbits. A circumferential scleral buckling implant was sutured episclerally on the left eye of each rabbit, just temporal to the superior rectus muscle and 7 mm posterior to the limbus. Computed tomography was performed at 1 week, 3 months, and 5 months after surgery. RESULTS The PLA96 buckling implant (implant diameter, 3-3.5 mm) used in this study created lower indentation than the silicone sponge implant (implant diameter, 4 mm). The indentation created by the PLA96 implant decreased over time compared with that created by the silicone implant. There were no complications related to either kind of implant. CONCLUSION Both the silicone sponge implant and the PLA96 implant caused indentation that decreased in a comparable manner over the follow-up period (5 months).
منابع مشابه
Orbital cellulitis following silicone-sponge scleral buckles
BACKGROUND Acute or chronic infection of the scleral explant is rare. We report seven cases of scleral explant infections that caused orbital cellulitis. MATERIALS AND METHODS This was a retrospective chart review of oculoplastics at oculoplastics and vitreo-retinal units in a secondary referral hospital. All subjects had orbital cellulitis secondary to scleral buckle in the range of January ...
متن کاملCircumferential silicone sponge scleral buckling induced axial length changes: case series and comparison to literature
BACKGROUND This study compared axial length changes induced by circumferential scleral buckling using a silicone sponge with literature reports for solid silicone rubber. METHODS Records of patients treated with scleral buckling in 2009-2013 using a silicone sponge, with preoperative axial length biometry measurements were reviewed. Additional information included age, type of surgery, additi...
متن کاملBioabsorbable miniplating versus metallic fixation for metacarpal fractures.
Bioabsorbable implants offer an attractive alternative to metallic implants to stabilize small bone fractures in the hand. Self-reinforced bioabsorbable miniplating for metacarpal fractures was studied in bones from cadavers and compared with standard metallic fixation methods. One hundred twelve fresh-frozen metacarpals from humans had three-point bending and torsional loading after transverse...
متن کاملLong-term complications of silicone and hydrogel explants in retinal reattachment surgery.
OBJECTIVE To compare long-term complications of silicone sponge, silicone rubber, and MIRAgel used as episcleral buckling elements. METHODS Medical reports were reviewed of 805 patients with cryotherapy and episcleral buckle for rhegmatogenous retinal detachment who were operated on by 1 of us (M.R.-P.) between March 1984 and December 1997. Average follow-up was 76 months. Symptoms and signs ...
متن کاملEarly findings in a pilot study of anterior cervical interbody fusion in which recombinant human bone morphogenetic protein-2 was used with poly(L-lactide-co-D,L-lactide) bioabsorbable implants.
OBJECT The goal of this study was to assess the efficacy of bioabsorbable interbody spacers in cervical spine fusion. METHODS The authors report on a prospective examination of 20 patients with degenerative cervical disc disease who underwent anterior cervical fusion at 28 total levels. The authors used Infuse bone graft (that is, recombinant human bone morphogenetic protein-2 applied to an a...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Retina
دوره 25 5 شماره
صفحات -
تاریخ انتشار 2005