Implantation of iris devices in congenital and traumatic aniridias: Surgery solutions and complications.
نویسندگان
چکیده
PURPOSE To show surgical solutions in patients with traumatic and congenital aniridia, to evaluate the clinical improvement of these patients when iris prosthesis are implanted, and to examine safety and complications of these implants in a long-term follow-up. METHODS Eight patients were included in this retrospective noncomparative case series. Nine eyes had an artificial iris implantation for traumatic or congenital aniridia. Three eyes received a black diaphragm intraocular lens (IOL) in capsular bag after phacoemulsification. An aniridia prosthesis, sulcus sutured, in front of a previous IOL was implanted in two eyes. A black diaphragm IOL, sulcus sutured, in two eyes; two iris diaphragm rings, in front of the previous IOL, in one eye; and a sector iris prosthesis in front of an IOL in the last eye were implanted. Mean follow-up was 22.5 months (range 16 to 44 months). RESULTS All patients had improved visual acuity (VA) and visual comfort after surgery. The glare disability was subjectively better in all cases. Two patients developed new ocular hypertension after surgery; one of them was controlled by medical treatment and the other needed cyclodiode. Two of the patients with glaucoma preoperatively also needed cyclodiode procedure and one of them an Ahmed valve. CONCLUSIONS Several kinds of artificial iris implants are available. In all our patients with aniridia, iris artificial prostheses improved VA and diminished visual discomfort. Glaucoma is the most important complication after artificial iris implant. It is possible to implant the iris prosthesis in the capsular bag, but this requires a large capsulorrhexis and presents a surgical challenge.
منابع مشابه
Cataract surgery with intraocular lens implantation in children aged 5-15 in local anaesthesia: visual outcomes and complications
The aim of this study was to report feasibility, the visual outcomes and complications of pediatric cataract surgery with primary intraocular lens implantation in children aged 5 to15 years in local anesthesia. This retrospective interventional case series included 62 eyes from 50 children who underwent pediatrc cataract surgery with primary intraocular lens implantation at the Mana eye Clinic ...
متن کاملComparative evaluation of LMA-Supreme and i-gel supraglottic airway devices with endotracheal intubation during surgical correction of traumatic orbital injuries
Aims. The aim of the study was to compare endotracheal intubation with i-gel and LMA (laryngeal mask airway) supreme supraglottic airway devices in orbital osteosynthesis surgery. Methods. 134 patients undergoing orbital plasty after fracture were enrolled in our study and were randomized into three groups: 43 in the endotracheal intubation group, 42 in the LMA-Supreme group, and 49 patients w...
متن کاملIntraocular lens implantation for patients with coloboma of the iris
The aim of this study was to analyze the techniques for intraocular lens (IOL) implantation in patients with coloboma of the iris. A retrospective cohort study was used to analyze the degree of iris coloboma and the characteristics of the crystalline lens in 56 patients with iris coloboma. The patients with a lesser degree of coloboma of the iris and an intact lens capsule were treated by iris ...
متن کاملPulsed electron avalanche knife: new technology for cataract surgery.
BACKGROUND The pulsed electron avalanche knife (PEAK-fc) is a new pulsed electrosurgical device that allows for precise, "cold" and traction-free tissue dissection. AIM To evaluate the surgical applicability, safety and potential complications of PEAK-fc in complicated cataract surgery. METHODS The study included five children with congenital cataracts, two patients with advanced senile cat...
متن کاملComparison between Limbal and Pars Plana Approaches Using Microincision Vitrectomy for Removal of Congenital Cataracts with Primary Intraocular Lens Implantation
Purpose. To compare the surgical outcomes of limbal versus pars plana vitrectomy using the 23-gauge microincision system for removal of congenital cataracts with primary intraocular lens implantation. Methods. We retrospectively reviewed all eyes that underwent cataract removal through limbal or pars plana incision. Main outcome measures included visual outcomes and complications. Results. We i...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- European journal of ophthalmology
دوره 15 4 شماره
صفحات -
تاریخ انتشار 2005