Receiver Cryogenic System
نویسندگان
چکیده
منابع مشابه
Design and construction of a helium purification system using cryogenic adsorption process
One of the most appropriate methods for elimination of trace impurities in helium is cryogenic adsorption process. So, in this study design and construction of cryogenic adsorption helium purification system (3 Nm3.hr-1, 80 bar) carried out using activated carbon as adsorbent at 77K. To evaluation of adsorption dynamics and effect of pressure on elimination of trace impurities, helium purificat...
متن کاملAnalysis of the Principal Characteristics of the On-Board Throttle Cooling System of the IR Receiver on the Basis of a Tank with Cryogenic Fueling
In this paper, a new tank with cryogenic charging (liquid nitrogen) is introduced. On the basis of this tank it is proposed to create a throttle cooling system, which may have enhanced characteristics compared with a throttle cooling system based on high pressure tank. This article deals with first results of tests of a tank with cryogenic charging (liquid nitrogen), which have been made at lev...
متن کاملHow to Design a Cryogenic Joule-Thomson Cooling System: Case Study of Small Hydrogen Liquefier
Heat exchangers are the critical components of refrigeration and liquefaction processes. Selection of appropriate operational conditions for cryogenic recuperative heat exchanger and expansion valve operating in Joule-Thomson cooling system results in improving the performance and efficiency. In the current study, a straightforward procedure is introduced to design an efficient Joule-Thomson co...
متن کاملThe C-Band All-Sky Survey (C-BASS): design and implementation of the northern receiver
The C-Band All-Sky Survey is a project to map the full sky in total intensity and linear polarization at 5 GHz. The northern component of the survey uses a broad-band singlefrequency analogue receiver fitted to a 6.1-m telescope at the Owens Valley Radio Observatory in California, USA. The receiver architecture combines a continuous-comparison radiometer and a correlation polarimeter in a singl...
متن کاملMethods for the Characterization and Measurement of the Gain Fluctuations of Cryogenic Amplifiers
Since ALMA instrument will have low noise receivers with very large instantaneous bandwidth, gain stability should be carefully specified to avoid limiting the sensitivity of the total system. This memorandum reviews the methods for the characterization of gain stability in the time and frequency domain and presents examples of experimental setups used for its measurement in the case of cryogen...
متن کامل