Influence of Different Patellofemoral Design Variations Based on Genesis II Total Knee Endoprosthesis on Patellofemoral Pressure and Kinematics

نویسندگان

  • Ulf G Leichtle
  • Barbara Lange
  • Yvonne Herzog
  • Peter Schnauffer
  • Carmen I Leichtle
  • Nikolaus Wülker
  • Andrea Lorenz
چکیده

In total knee arthroplasty (TKA), patellofemoral groove design varies greatly and likely has a distinct influence on patellofemoral biomechanics. To analyse the selective influence, five patellofemoral design variations were developed based on Genesis II total knee endoprosthesis (original design, being completely flat, being laterally elevated, being medially elevated, and both sides elevated) and made from polyamide using rapid prototyping. Muscle-loaded knee flexion was simulated on 10 human knee specimens using a custom-made knee simulator, measuring the patellofemoral pressure distribution and tibiofemoral and patellofemoral kinematics. The measurements were carried out in the native knee as well as after TKA with the 5 design prototypes. The overall influence of the different designs on the patellofemoral kinematics was small, but we found detectable effects for mediolateral tilt (p < 0.05 for 35°-80° flexion) and translation of the patella (p < 0.045 for 20°-65° and 75°-90°), especially for the completely flat design. Considering patellofemoral pressures, major interindividual differences were seen between the designs, which, on average, largely cancelled each other out. These results suggest that the elevation of the lateral margin of the patellofemoral groove is essential for providing mediolateral guidance, but smooth contouring as with original Genesis II design seems to be sufficient. The pronounced interindividual differences identify a need for more patellofemoral design options in TKA.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Differences in the stress distribution in the distal femur between patellofemoral joint replacement and total knee replacement: a finite element study

BACKGROUND Patellofemoral joint replacement is a successful treatment option for isolated patellofemoral osteoarthritis. However, results of later conversion to total knee replacement may be compromised by periprosthetic bone loss. Previous clinical studies have demonstrated a decrease in distal femoral bone mineral density after patellofemoral joint replacement. It is unclear whether this is d...

متن کامل

Comparison of the effects of external instruction exercises in combination with hip-knee strengthening on gait kinematics in patients with patellofemoral pain syndrome: a randomized clinical trial.

Aims and Background: Patellofemoral pain syndrome is one of the most common musculoskeletal disorders, and is related to biomechanical factors of the lower extremities. The purpose of this study was to compare the effect of hip and knee strengthening with internal instruction exercises on pain and dynamic knee valgus in patients with Patellofemoral pain syndrom. Materials and Methods: 50 men a...

متن کامل

Comparisons of bracing and patellar taping on knee three-dimensional kinematics of women with patellofemoral pain syndrome in stance phase of running

Introduction: Patellofemoral pain syndrome (PFPS) is one of the most common knee injuries that accounted for between 25-40% of all knee problems presenting to sports medicine centers. Two treatment methods of bracing and taping are recommended in these patients that their effectiveness are unclear. The aim of this study was to evaluate the efficacy of the two treatment methods on knee three-dim...

متن کامل

The Influence of Tibial Tuberosity-trochlear Groove Distance on Development of Patellofemoral Pain Syndrome

Background: Tibial tuberosity-trochlear groove distance (TT-TGD) measurements play a decisive role in evaluatingpatellofemoral joint disorders. However, the prevalence of pathological TT-TGD among patients with patellofemoralpain remains unclear. The purpose of this study was to compare the size of TT-TGD among patients with patellofemoralpain syndrome (PFPS) and those with no history of patell...

متن کامل

Simultaneous in vitro measurement of patellofemoral kinematics and forces.

This study involved the development and testing of a system for the simultaneous in vitro measurement of tibiofemoral kinematics and patellofemoral kinematics and forces. Knee motion was tracked using a Vicon 370, and patellofemoral force was measured using a six degree-of-freedom transducer based on the design of Singerman et al. Using this system, twelve knee specimens were tested in supine l...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2017  شماره 

صفحات  -

تاریخ انتشار 2017