Reproducibility of corneal astigmatism measurements with a hand held keratometer in preschool children.
نویسندگان
چکیده
AIMS To evaluate the overall accuracy and reproducibility of the Alcon portable autokeratometer (PAK) measurements in infants and young children. METHODS The accuracy of the Alcon PAK in measuring toric reference surfaces (1, 3, 5, and 7 D) under various suboptimal measurement conditions was assessed, and the reproducibility of PAK measurements of corneal astigmatism in newborn infants (n = 5), children (n = 19, age 3-5 years), and adults (n = 14) was evaluated. RESULTS Measurements of toric reference surfaces indicated (a) no significant effect of distance (17-30 mm) on accuracy of measurements, (b) no systematic relation between amount of toricity and accuracy of measurements, (c) no systematic relation between angle of measurement and accuracy, (d) no difference in accuracy of measurements when the PAK is hand held in comparison with when it is mounted, (e) no difference in accuracy of measurements when axis of toricity is oriented obliquely than when it is oriented horizontally, with respect to the PAK, and (f) a small positive bias (+0.16 D) in measurement of spherical equivalent. The PAK did not prove useful for screening newborns. However, measurements were successfully obtained from 18/19 children and 14/14 adults. There was no significant difference in median measurement deviation (deviation of a subject's five measurements from his/her mean) between children (0.21 D) and adults (0.13 D). CONCLUSIONS The PAK produces accurate measurements of surface curvature under a variety of suboptimal conditions. Variability of PAK measurements in preschool children is small enough to suggest that it would be useful for screening for corneal astigmatism in young children.
منابع مشابه
Reliable keratometry with a new hand held surgical keratometer: calibration of the keratoscopic astigmatic ruler.
AIM Some surgeons consider hand held surgical keratometers unreliable. This may be due to incorrect use through not realising that the distance that the keratometer is held from the cornea influences the shape of the image. When a keratometer is held closer to the astigmatic cornea, the elliptical image will appear more circular, particularly for larger degrees of astigmatism. However, the kera...
متن کاملPrevalence of corneal astigmatism in Tohono O'odham Native American children 6 months to 8 years of age.
PURPOSE To describe the prevalence of corneal astigmatism in infants and young children who are members of a Native American tribe with a high prevalence of refractive astigmatism. METHODS The prevalence of corneal astigmatism was assessed by obtaining infant keratometer (IK4) measurements from 1235 Tohono O'odham children, aged 6 months to 8 years. RESULTS The prevalence of corneal astigma...
متن کاملWhich Keratometer is Most Reliable for Correcting Astigmatism with Toric Intraocular Lenses?
PURPOSE To evaluate the accuracy of preoperative keratometers used in cataract surgery with toric intraocular lens (IOL). METHODS Twenty-five eyes received an AcrySof toric IOL implantation. Four different keratometric methods, a manual keratometer, an IOL master, a Pentacam and an auto keratometer, were performed preoperatively in order to evaluate preexisting corneal astigmatism. Difference...
متن کاملScreening for refractive errors in children: accuracy of the hand held refractor Retinomax to screen for astigmatism.
AIMS To assess the reliability of the hand held automated refractor Retinomax in measuring astigmatism in non-cycloplegic conditions. To assess the accuracy of Retinomax in diagnosing abnormal astigmatism in non-cycloplegic refractive screening of children between 9 and 36 months. METHODS Among 1205 children undergoing a non-cycloplegic refractive screening with Retinomax, 299 (25%) had repea...
متن کاملEffectiveness and confounding factors of penetrating astigmatic keratotomy in clinical practice
RATIONALE Penetrating astigmatic keratotomy (penetrating AK) is a well-known method to correct corneal astigmatism but rarely be performed nowadays. This article reevaluated the clinical effectiveness and confounding factors of penetrating AK. PATIENT CONCERNS Penetrating AK has been introduced to serve as one alternative operation for astigmatism correction, and is thought to have the potent...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The British journal of ophthalmology
دوره 79 11 شماره
صفحات -
تاریخ انتشار 1995