Mechanical properties of the tendinous equine interosseus muscle are affected by in vivo transducer implantation.

نویسندگان

  • M O Jansen
  • H C Schamhardt
  • A J van den Bogert
  • W Hartman
چکیده

Liquid metal strain gauges (LMSGs) were implanted in the tendinous interosseous muscle, also called suspensory ligament (SL), in the forelimbs of 6 ponies in order to quantify in vivo strains and forces. Kinematics and ground reaction forces were recorded simultaneously with LMSG signals at the walk and the trot prior to implantation, and 3 and 4 days thereafter. The ponies were euthanised and tensile and failure tests were performed on the instrumented tendons and on the tendons of the contra lateral limb, which were instrumented post mortem. The origo-insertional (OI) strain of the SL was computed from pre- and post-operative kinematics, using a 2D geometrical model. The LMSG-recorded peak strain of the SL was 5.4+/-0.9% at the walk and 9.1+/-1.3% at the trot. Failure occurred at 15.4+/-2.1% (mean+/-S.D.). The LMSG strain was higher than the simultaneously recorded OI strain 0.5+/-0.7% strain at the walk and 2.2+/-1.1% strain at the trot. Post-operative OI strains were only slightly higher than pre-operative values. Failure strains of in vivo instrumented SLs were 2.0+/-1.2% strain higher, and failure forces were slightly lower, than those of the contra lateral SLs that were instrumented post mortem. SL strains appeared to be considerably higher than those found in earlier acute experiments. Differences between in vivo LMSG and OI strains, supported by lower failure strains comparing in vivo and post mortem instrumented SLs, revealed that local changes in tendon mechanical properties occurred within 3 to 4 days after transducer implantation. Therefore, measurements of normal physiological tendon strains should be performed as soon as possible after transducer implantation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Mechanical properties of tendon and aponeurosis of human gastrocnemius muscle in vivo.

Load-strain characteristics of tendinous tissues (Achilles tendon and aponeurosis) were determined in vivo for human medial gastrocnemius (MG) muscle. Seven male subjects exerted isometric plantar flexion torque while the elongation of tendinous tissues of MG was determined from the tendinous movements by using ultrasonography. The maximal strain of the Achilles tendon and aponeurosis, estimate...

متن کامل

Design and Fabrication of a Longitudinal-Torsional Ultrasonic Transducer

A hybrid longitudinal-torsional ultrasonic transducer is designed and fabricated in this research. The design of the transducer was performed using the FE method with ABAQUS software, with the aim of combining the longitudinal and torsional vibration modes. The transducer horn is then fabricated using a 4-axis milling machine. The PZT stacks are employed in order to excite the transducer. The t...

متن کامل

Estimation of spinal loads using a detailed finite element model of the L4-L5 lumbar segment derived by medical imaging kinematics; a feasibility study

Introduction: Low back pain is the most prevalent orthopedic disorder and the first main cause of poor working functionality in developed as wells as many developing countries. In Absence of noninvasive in vivo measurement approaches, biomechanical models are used to estimate mechanical loads on human joints during physical activities. To estimate joint loads via musculoskelet...

متن کامل

Design and Fabrication of a Longitudinal-Torsional Ultrasonic Transducer

A hybrid longitudinal-torsional ultrasonic transducer is designed and fabricated in this research. The design of the transducer was performed using the FE method with ABAQUS software, with the aim of combining the longitudinal and torsional vibration modes. The transducer horn is then fabricated using a 4-axis milling machine. The PZT stacks are employed in order to excite the transducer. The t...

متن کامل

Effect of Graphene Oxide Nanoparticles Addition on Mechanical and Biological Properties of Calcium Phosphate Cement

In the present study, we have evaluated the effects of graphene oxide (GO) addition on the physical-mechanical-biological properties of calcium phosphate cement (CPC). The in vitro cellular responses of MG63 and in vivo tissue responses after the implantation of CPC/GO in parietal bone defects of   wistar rats were also investigated. The brushite calcium phosphate cements were prepared by mixi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of biomechanics

دوره 31 5  شماره 

صفحات  -

تاریخ انتشار 1998