Incidence and specificity of interference in two-site immunoassays.
نویسندگان
چکیده
Using a modified "two-site" immunoradiometric assay, termed an "interference assay," we have demonstrated the occurrence of non-analyte antibody-binding substances in approximately 40% of serum samples. These substances multivalently bind antibodies from any of several species at a site other than the antigen-binding site. Using a two-site immunoradiometric assay for human choriogonadotropin, we have investigated their effect on analyte quantification. In this system these antibody-binding substances mimic the presence of analyte; when analyte is actually present, they can also cause over- or underestimates. Addition of excess nonspecific immunoglobulin from an appropriate species eliminates this interference. However, the amount of nonspecific immunoglobulin added to an assay system may not always be enough to block interference in all samples.
منابع مشابه
Interference in immunoassays: avoiding erroneous results
types of immunoassay interference are similar to interferences in other chemistry assays and some types are unique to immunoassays. The interfering substance (interferent) in the sample may be exogenous to the patient, for example a drug, or endogenous, for example antibodies produced by the patient. The bias caused by interference may be positive or negative and, in some cases, the degree and ...
متن کاملTowards narrower analytical goals in routine laboratory work.
596 CLINICAL CHEMISTRY, Vol. 37, No. 4, 1991 1. Howanitz PJ, Howanitz JH, Lamberson HV, Ennis KM. Incidence and mechanism of spurious increases in serum thyrotropin. Clin Chem 1982;28:427-31. 2. Boscato LM, Stuart MC. Incidence and specificity of interference in two-site inununoassays. Clin Chem 1986;32:1491-5. 3. Boscato LM, Stuart MC. Heterophilic antibodies: a problem for all immunoassays. C...
متن کاملInterferences in Immunoassays
Interference in immunoassays is a serious but underestimated problem (Ismail et al, 2002a). Interference is defined as “the effect of a substance present in the sample that alters the correct value of the result, usually expressed as concentration or activity, for an analyte” (Kroll & Elin, 1994). Immunoassays are analytically sensitive and measurements can frequently performed without prior ex...
متن کاملPrevalence of anti-HBc in HBsAg negative blood donors using two enzyme immunoassays kits
Abstract Background and Objectives Use of kits with high sensitivity and specificity to determine the prevalence of antibodies against hepatitis B virus (anti-HBc) core antigen is important. The aim of this study was to determine the prevalence of hepatitis B virus antibody in HBsAg negative blood donors using two anti-HBc enzyme immunoassay kits (DIA.PRO and SIEMENS). Materials and Methods...
متن کاملDemonstration and minimization of serum interference in flow cytometric two-site immunoassays.
The ability of serum factors to cross-link labeled mouse monoclonal antibody (mAb) of irrelevant specificity (mAb FN61, subclass IgG1) to different particle types coated with sheep IgG, bovine gamma-globulin, or mAb FN61 was measured simultaneously by flow cytometry. Significant interference with mAb FN61-coated particles was detected in 53 of 101 sera. Of the 30 sera showing the most pronounce...