Characterization of the new serum protein reference material ERM-DA470k/IFCC: value assignment by immunoassay.

نویسندگان

  • Ingrid Zegers
  • Thomas Keller
  • Wiebke Schreiber
  • Joanna Sheldon
  • Riccardo Albertini
  • Søren Blirup-Jensen
  • Myron Johnson
  • Stefanie Trapmann
  • Hendrik Emons
  • Giampaolo Merlini
  • Heinz Schimmel
چکیده

BACKGROUND The availability of a suitable matrix reference material is essential for standardization of the immunoassays used to measure serum proteins. The earlier serum protein reference material ERM-DA470 (previously called CRM470), certified in 1993, has led to a high degree of harmonization of the measurement results. A new serum protein material has now been prepared and its suitability in term of homogeneity and stability has been verified; after characterization, the material has been certified as ERM-DA470k/IFCC. METHODS We characterized the candidate reference material for 14 proteins by applying a protocol that is considered to be a reference measurement procedure, by use of optimized immunoassays. ERM-DA470 was used as a calibrant. RESULTS For 12 proteins [α(2) macroglobulin (A2M), α(1) acid glycoprotein (orosomucoid, AAG), α(1) antitrypsin (α(1)-protease inhibitor, AAT), albumin (ALB), complement 3c (C3c), complement 4 (C4), haptoglobin (HPT), IgA, IgG, IgM, transferrin (TRF), and transthyretin (TTR)], the results allowed assignment of certified values in ERM-DA470k/IFCC. For CRP, we observed a bias between the lyophilized and liquid frozen materials, and for CER, the distribution of values was too broad. Therefore, these 2 proteins were not certified in the ERM-DA470k/IFCC. Different value transfer procedures were tested (open and closed procedures) and found to provide equivalent results. CONCLUSIONS A new serum protein reference material has been produced, and values have been successfully assigned for 12 proteins.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Commutability of the ERM-DA470k reference material for two assays measuring serum albumin using immunochemical principles.

The standardization of measurements is a high-priority in Laboratory Medicine; its purpose being to achieve closer comparability of results for the same analyte obtained using different commercial systems (1). The promotion of result traceability to available higher-order reference measurement procedures and reference materials is the recommended approach (2). A major prerequisite for guarantee...

متن کامل

The importance of commutability of reference materials used as calibrators: the example of ceruloplasmin.

BACKGROUND Different methods for ceruloplasmin tend to give different results in external quality assessment schemes. During the production of the certified reference material ERM-DA470k/IFCC discrepant measurement results were also found for ceruloplasmin measured with different methods, and consequently the protein could not be certified in the material. METHODS We performed a commutability...

متن کامل

CERTIFICATION REPORT The certification of the mass concentration of beta-2-microglobulin in human serum: ERM-DA470k/IFCC

This report describes the additional certification of the mass concentration of beta-2-microglobulin (B2M) in ERM-DA470k/IFCC, a human serum material. The material was released in 2008 and was certified for the mass concentration of 12 proteins in human serum. The material is now additionally certified for B2M in accordance with ISO Guide 34:2009. A full description of the processing steps used...

متن کامل

Analysis of the physicochemical state of C-reactive protein in different preparations including 2 certified reference materials.

BACKGROUND Standardization of clinical measurements of C-reactive protein (CRP) is based on the availability of reference materials. The serum protein reference material ERM-DA470 was used as a calibrant for various commercially available immunoassays but has now been exhausted. The recently released ERM-DA470k/IFCC was intended to fully replace ERM-DA470. However, the new material was not suit...

متن کامل

Protein standardization V: value transfer. A practical protocol for the assignment of serum protein values from a Reference Material to a Target Material International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) IFCC Scientific Division

We present a practical protocol for the assignment of values to serum proteins in a Target Material using a Reference Material. This protocol is based on the model of Direct Value Transfer between serum matrices and is intended to improve the value assignment of commercial calibrators using the Reference Material CRM 470 (now labeled ERM-DA 470) or similar The exclusive for all languages and co...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Clinical chemistry

دوره 56 12  شماره 

صفحات  -

تاریخ انتشار 2010