The effect of electrode configuration on the unipolar His-bundle electrogram.
نویسندگان
چکیده
Although "unipolar electrograms" recorded from the His-bundle position have been used to help position catheters for His-bundle ablation, the techniques used to record such electrograms have not been standardized. The effects of five anode locations (right chest wall, anterior chest wall, left chest wall, posterior chest wall, and inferior vena cava) on unipolar atrial, His bundle and ventricular electrograms recorded from the His-bundle position were examined in ten patients undergoing clinical electrophysiology studies. Electrograms were recorded at filter settings of 50-500 as well as 0.05-1000 Hz. The location of the anode had no consistent effect on the amplitude, duration or morphology of any of the electrograms at either filter setting, but signals recorded with the inferior vena cava anode had the highest signal-to-noise ratio. A filter setting of 50-500 Hz decreased the amplitude of atrial (0.72 to 0.33 mV-P less than 0.01), His bundle (0.38 vs 0.32 mV-P less than 0.01) and ventricular electrograms (3.71 vs 2.01 mV-P less than 0.001) compared to a filter setting of 0.05-1,000 Hz. The filter setting did not affect electrogram duration. We concluded that the use of an electrode catheter in the inferior vena cava as the anode when recording "unipolar electrograms" from the His-bundle position yields a better signal-to-noise ratio than a skin patch on the chest and appears to be the optimal method for recording unipolar electrograms.
منابع مشابه
Nature of His potential in His electrogram.
Unipolar His bundle electrograms were recorded with the muscle preparation isolated from the rabbit or the dog heart at as various sites as possible on and near the A-V conduction system and changes in appearance time and configuration of the so-called His (H) potential were examined. When the exploring electrode was shifted from the coronary sinus orifice down to the transition between the A-V...
متن کاملUsefulness of unipolar electrograms to detect isthmus block after radiofrequency ablation of typical atrial flutter.
BACKGROUND RS morphology of the unipolar electrogram is associated with propagation of the wave front through the exploring electrode, whereas positive uniphasic (R) unipolar electrograms are characteristic of the end of activation. METHODS AND RESULTS Unipolar electrograms were recorded in 45 consecutive patients with atrial flutter who were undergoing radiofrequency ablation (RFA). Bidirect...
متن کاملLow-energy transvenous ablation of the canine atrioventricular conduction system with a suction electrode catheter.
A single suction electrode catheter was used for His bundle electrogram recording. His bundle pacing, and low-energy (20 or 30 J) His bundle ablation in seven dogs. The suction electrode catheter was actively fixed to the atrial endocardium at the His bundle level. Electrophysiologic studies were performed in the control state, immediately after, and late (greater than 40 days) after His bundle...
متن کاملOvercoming left bundle branch block by permanent His bundle pacing: Evidence of longitudinal dissociation in the His via recordings from a permanent pacing lead
Introduction Narrowing of the QRS and overcoming left bundle branch block (LBBB) with His bundle pacing (HBP) has been previously described. We present the first 2 reported cases of left bundle branch (LBB) delay with evidence of a split His electrogram during unipolar mapping from the tip of the His bundle (HB) lead during pacemaker implantation. These findings suggest that the site of LBB del...
متن کاملIntraoperative recording of the His bundle electrogram in man. An assessment of its precision.
To estimate the effect of distance between the electrode and the signal source on the amplitude of the His bundle electrogram (HBE) recorded during open heart surgery, a specially designed probe, containing six pairs of closely spaced (1 mm) electrodes was placed on the endocardial surface of the right atrium such that each electrode pair was parallel to the course of the His bundle. The amplit...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Pacing and clinical electrophysiology : PACE
دوره 12 9 شماره
صفحات -
تاریخ انتشار 1989